nL, nH=0~255. Horizontal or vertical minimal unit is specified by GS P.
GS f
Format:
ASCII:
Decimal:
Hex:
Description:
Select the HRI character when printing a bar code:
n=0, 48; Selects character A (12*24)
n=1, 49; Selects character B (8*16)
GS h
Format:
ASCII:
Decimal:
Hex:
Description:
Set the height of the bar code to n dots.
n=0~255.
GS k
Format:
ASCII:
Decimal:
Hex:
*
ASCII:
Decimal:
Hex:
*when m>64
m
Bar code type
0
UPC-A
1
UPC-E
2
EAN13
3
EAN8
4
CODE39
5
ITF
6
CODABAR
*65
UPC-A
*66
UPC-E
*67
EAN13
*68
EAN8
*69
CODE39
CODESOFT PL-330 User's Manual
GS
h
n
29
102
n
1D
66
n
GS
h
n
29
104
n
1D
68
n
GS
k
m
29
107
m
1D
6B
m
GS
k
m
29
107
m
1D
6B
m
Amount of data
Fixed
Fixed
Fixed
Fixed
Can be changed
Can be changed
Can be changed
Fixed
Fixed
Fixed
Fixed
Can be changed
d1..dk
NUL
d1..dk
0
d1..dk
00
n
d1..dn
n
d1..dn
n
d1..dn
Number of
Character
characters
11≤k≤12
0~9
11≤k≤12
0~9
12≤k≤13
0~9
7≤k≤8
0~9
0~9, A~Z,
SP, $, %, +,
1≤k
-, ., /
* (start, stop)
1≤K (even)
0~9
0~9, A~D,
1 ≤ k
$, +, -, ., /, :
11≤n≤12
0~9
11≤n≤12
0~9
12≤n≤13
0~9
7≤n≤8
0~9
0~9, A~Z,
SP, $, %, +,
1≤n<255
-, ., /
* (start, stop)
- 67 -
Select the HRI character font
Set bar code height
Print bar code
Character code
48≤d≤57
48≤d≤57
48≤d≤57
48≤d≤57
48≤d≤57,
65≤d≤90,
d=32, 36, 37, 43, 45, 46,
47. d=42 (start, stop)
48≤d≤57
48≤d≤57, 65≤d≤68, 36,
43, 45, 46, 47, 58
48≤d≤57
48≤d≤57
48≤d≤57
48≤d≤57
48≤d≤57, 65≤d≤90d=32,
36, 37, 43, 45, 46, 47.
d=42 (start, stop)