VISTA-128BPT/128BPT-SIA/250BPT INSTALLATION AND SETUP GUIDE
UL365 Police Station Connected Burglar Alarm
Follow the instructions for UL609 local installations given above.
For Systems without Line Security:
You may use the VISTA-128BPT/VISTA-250BPT
dialer alone, or the 7847i Communicator alone.
When using the dialer, program it to send Burglary
Alarm, Low Battery, and Communicator Test reports.
Field ∗27 must be set to "0024" (or less).
If you are using the 7847i Communicator, connect it
to the VISTA-128BPT/VISTA-250BPT
burglary/audible panic alarm trigger.

UL611/UL1610 Central Station Burglary Alarm

Follow the instructions for UL609 Local installations given above.
For Systems without Line Security:
You must use the VISTA-128BPT/VISTA-250BPT'
dialer with a 7847i Communicator.
Connect the control's burglary/audible panic alarm
trigger (on J7 header) and the 659EN's phone line
monitor output to the 7847i. The 7847i will send a
report to the central station when a telephone line
fault condition is detected.
California State Fire Marshal (CSFM) and UL Residential Fire Battery Backup
Requirements
The California State Fire Marshal and UL have regulations
that require all residential fire alarm control panels to have
backup battery with sufficient capacity to operate the
panel and its attached peripheral devices for 24 hours in
the intended standby condition, followed by at least 4
minutes in the intended fire alarm signaling condition.
The VISTA-128BPT/VISTA-250BPT can meet this
requirement without using a supplemental power supply,
provided that the panel's outputs (including the current
drawn from the auxiliary power output terminals) are
limited as shown below:

ULC Installation Requirements

The zone inputs of the control unit are considered
Low Risk applications only.
The control unit must not be mounted on the exterior
of a vault, safe or stockroom.
Subscriber control units capable of maintaining
opening (disarming) and closing (arming) schedules
must facilitate a hardcopy printout of the opening
(disarming) and closing (arming) schedule
programming and of all the programmed holidays.
Telephone service must be of the type that provides
for timed release disconnect.
A server employed for control over network
addressing, encryption or re-transmission, Must be
designed to remain in the "on state" at all times.
Encryption must be enabled at all times for active
communications channel security.
For Systems with Line Security:
You must use a GSMHS Communicator.
Also connect the 7847i Communicator's fault output
to one of the VISTA-128BPT/VISTA-250BPT EOLR-
supervised zones (i.e., 1-8). Program this zone for a
trouble by day/alarm by night (type 05) or a 24-hour
alarm (type 07, 08) response to communicator's
faults.
Program the control's dialer to send Burglary Alarm,
Trouble, Opening/Closing, and Low Battery reports.
For Systems with Line Security:
Follow the instructions for Systems without Line Security,
except use the GSMHS Communicator in place of the
7847i.
Output current is limited to 750mA maximum total
auxiliary power, polling loop, and bell output current.
Maximum auxiliary current is 300mA (including
polling loop current).
A 14AH battery is used. (Yuasa model NP7-12
recommended; use two connected in parallel.) A
dual-battery harness is provided with ADEMCO No.
4100EOLR Resistor Kit (kit also contains EOL
resistors having spade lug/heat shrink tubing
construction approved by UL and CSFM for fire zone
usage). Both batteries fit inside the panel's cabinet.
For ULC Installations, refer to CAN/ULC-S302,
Installation and Classification of Burglar Alarm
Systems for Financial and Commercial Premises,
Safes and Vaults; CAN/ULC-S301, Standard for
Central and Monitoring Station Burglar Alarm
systems and CSA 22.1, Canadian Electrical Code,
Part I, Safety Standard for Electrical Installations.