Telephone Line Connections; Figure 16: Disabling Bell Supervision; Figure 17: Telephone Line Connections; Reporting Formats - Honeywell VISTA-128BPT Installation And Setup Manual

Commercial burglary partitioned security system with scheduling
Hide thumbs Also See for VISTA-128BPT:
Table of Contents

Advertisement

Disabling the Supervision of the Alarm Output
1.
Wire the devices to terminals 4 and 5,
observing polarity if necessary.
2.
Cut the blue jumper on the upper left-hand
corner of the panel's PC board.
3.
Program Zone 970 with no response type (00).

Telephone Line Connections

Connect the main dialer output to telephone company lines using the cable supplied.
UL
The telephone line inputs have overvoltage protection in accordance with UL1459, as specified in
UL985/UL1023.
The system is shipped defaulted for Contact ID format. It is the only format capable of uniquely reporting all
250 zones, as well as openings and closings for all 250 users. This requires central stations to be equipped
with the Honeywell MX8000 receiver or equivalent.
To prevent the risk of shock, disconnect phone lines at the telco jack before servicing.
If the communicator is connected to a PABX, be sure it has a backup power supply that can support the
PABX for 24 hours (central station) or 60 hours (remote station). Many PABXs are not power-backed up, and
this can result in a communication failure if power is lost.

Reporting Formats

The system supports the following
formats:
ADEMCO Contact ID
ADEMCO 10-Digit Contact ID
4 + 2 Express.
SECTION 4: INSTALLING THE CONTROL

Figure 16: Disabling Bell Supervision

Figure 17: Telephone Line Connections

4-17