UL Installation Requirements
The following requirements apply to both UL
Residential and UL Commercial Burglary installations:
•
All partitions must be owned and managed by the
same person(s).
•
All partitions must be part of one building at one
street address.
•
The audible alarm device(s) must be placed where
it/they can be heard by all partitions.
•
The control cabinet must be protected from
unauthorized access. This can be done by
installing a tamper switch on the cabinet door
(not supplied with VISTA-128BPT/VISTA-250BPT)
or by installing a UL Listed passive infrared
UL609 Local Mercantile Premises/Local Mercantile Safe & Vault
Use the following guidelines for a Local Mercantile Premises/Local Mercantile Safe & Vault installation:
•
All zones must be configured for EOLR
supervision (∗41=0). Wireless sensors may not be
used. If 4190WH V-PLEXs are used set field ∗24
to "0" to enable tamper detection.
•
Attach a door tamper switch (supplied) to the
VISTA-128BPT/VISTA-250BPT cabinet backbox.
For safe and vault installations, a shock sensor
(not supplied) must also be attached to the
backbox. (Also see SECTION 3: Installing the
Control)
UL365/UL609 Bank Safe and Vault Alarm System
•
Follow the instructions for UL609 local
installations above and Bank/Mercantile Safe and
Vault (page 59) sections of this manual.
•
Bell 1 Confirmation of Arming Ding (∗16) must be
set to 1 to on (enabled) (will automatically test
bell).
•
Entry delays or any other delays to report alarms
may not exceed 45 seconds.
•
Models 7847i, 7847i-E, IGSMV, and IGSMHS
Section 12 : Agency Statements
detector positioned to detect cabinet access. Wire
the selected device to any EOLR-supervised zone
(Zone 1-8). Program this zone for day
trouble/night alarm (type 05) or 24-hour audible
alarm (type 07) response. The 24-hour alarm
response must be used for multiple-partitioned
systems.
•
Remote downloading and auto-disarming are not
UL Listed features.
NOTE: UL Commercial Burglary installations
•
Wire an ADEMCO AB12M Bell/Box to the bell
output. Bell wires must be run in conduit. Program
the bell output for a timeout of 16 minutes or
longer timeout and for confirmation of arming
ding. (Also see SECTION 3: Installing the Control.)
•
Wire the VISTA-128BPT/VISTA-250BPT tamper
switch and AB12M Bell/Box tamper switches to
any EOLR-supervised zone (zones 1-8). Program
this zone for day trouble/night alarm (type 05) or
24-hour audible alarm (type 07) response. The
24-hour alarm response must be used for
multiple-partitioned systems.
•
Entry delays must not exceed 45 seconds, and
exit delays must not exceed 60 seconds.
•
Bell Timeout must be programmed for 16 minutes
min.
•
Two 17.2AH Batteries must be used for this
application.
•
The main protective circuits, linings and
attachments on the safe and vault, control units
and alarm housing must be of the normally closed
circuit, fully supervised type.
•
To be installed inside the safe or vault.
12-3
require the attack resistant cabinet. The
cabinet is included in the VISTA-ULKT kit.