• You must program Bypass and Auto-Arm Fail reports for UL installations.
UL
• Auto-disarming is not permitted in UL installations.
• You must not program Random Scheduling of Time Driven Events for UL installations.
ULC
Scheduling is not approved for use in ULC installations.

General

The scheduling features allow certain operations to be automated, such as arming, disarming, bypassing of zones,
and activating relay outputs.
The system uses time windows (a programmed period of time with a start and stop time) for defining open/close
schedules, holiday schedules, user-defined temporary schedules, and access schedules for users.
Scheduled events are programmed by user-friendly menu modes of programming (#80, #81, #83, and #93 modes),
explained in detail in this section. These menus take you step by step through the options.

Auto Arming

ULC
Auto Arming is not a ULC Listed feature.
The system can automatically arm (AWAY Mode) a
partition at the end of a pre-determined closing
(arming) time window.
Auto Arming can be delayed three ways: by use of the
Auto-Arm Delay, the Auto-Arm Warning, or by
manually extending the closing (arming) time
window with a keypad command.
The system can also automatically bypass any open
zones when auto arming.
Common Lobby Notes:
Auto-Arm Delay (2∗05)
Auto-Arm Delay provides a delay (grace period)
before auto arming. It starts at the end of the closing
time window.
The delay is set in 4-minute increments, up to 56
minutes in partition-specific program field 2∗05. At
the expiration of this delay, the Auto-Arm Warning
will start.

Section 5 : Scheduling

If scheduling is used to automatically to arm and/or
disarm partitions, the common lobby
partition does not automatically follow another
partition that is programmed to arm or disarm the
lobby.
The lobby must be included as a partition to be
armed/disarmed and must be scheduled as the last
partition armed.
If using O/C schedules the panel will auto arm in the
AWAY Mode and if reporting O/C reports this reports
as CID Code 403 User number 0.
NOTE: Alarm Memory will not prevent an Auto Arm.
Auto-Arm Warning (2∗06)
The Auto-Arm Warning causes the keypad sounder
to warn the user of an impending Auto-Arm.
The warning can be set from 1 to 15 minutes prior to
the arming in partition-specific program field 2∗06.
During this period the keypad beeps every 15
seconds and displays "AUTO ARM ALERT." During
the last 60 seconds, the keypads beep every 5
seconds.
The panel arms at the conclusion of the Auto-Arm
Warning period.
5-1