Honeywell VISTA-128BPT Installation And Setup Manual page 68

Commercial burglary partitioned security system with scheduling
Hide thumbs Also See for VISTA-128BPT:
Table of Contents

Advertisement

VISTA-128BPT/128BPT-SIA/250BPT INSTALLATION AND SETUP GUIDE
After entering Scheduling Menu Mode, press [0] until the "Timed Events ?" prompt appears.
PROMPT
Timed Events ?
1 = YES 0 = NO
TIMED EVENT # ?
01-20, 00=Quit
01 ACTION ?
None
ACTION CODES
01 = Relay On
02 = Relay Off
03 = Relay Close for 2
seconds
04 = Relay Close XX minutes
05 = Relay Close YY seconds
06 = Relay Group On
07 = Relay Group Off
08 = Relay Group Close for 2
seconds
09 = Relay Group Close XX
minutes
10 = Relay Group Close YY
seconds
20 = Arm-STAY
21 = Arm AWAY
22 = Disarm
23 = Force Arm STAY
24 = Force Arm AWAY
25 = Arm INSTANT
26 = Arm MAXIMUM
40 = Enable Open Window by
Part.
41 = Enable Close Window by
Part.
30 = Auto bypass – Zone List
31 = Auto unbypass – Zone
List
42 = Enable Access Window
for Access group(s)
55 = Access Point Grant
56 = Access Point Grant
w/Override
57 = Access Point Protect
58 = Access Point Bypass
59 = Access Point Lock
60 = Access Point Exit
EXPLANATION
Enter 1 to program timed events.
0
Enter the timed event number to be programmed (01-20).
Press [∗].
01
The system then prompts the user to enter the desired action to be taken.
Enter 00 at the "TIMED EVENT #?" prompt to quit the timed event menus and display the "Quit
?" prompt.
Enter the action code for this timed-event number from the list at the left. This could be an
output command, an arming command, or any other Time-Driven event.
00
Press [∗] to accept the entry. The prompt for the action specifier appears.
EXPLANATION
Actions 01-05
If you selected actions 01-05, the prompt at the right
appears. Enter the relay number.
Press [∗] to accept entry. The "Time Window ?" prompt
appears.
Actions 06-10
If you selected actions 06-10, the prompt at the right
appears. Enter the relay group number.
Press [∗] to accept entry. The "Time Window ?" prompt
appears.
Actions 21-26 and 40-41
If you selected actions 21-26 or 40-41, the prompt at the
right appears. Enter the partition to which the action applies.
Enter 0 to select all partitions. Enter a partition number again
to deselect it.
Press [∗] to accept entry. The "Time Window ?" prompt
appears.
Actions 30-31
If you selected actions 30-31, the prompt at the right
appears. Enter the zone list number that contains the zones
to be bypassed or unbypassed.
Press [∗] to accept entry. The "Time Window ?" prompt
appears.
Action 42
If you selected action 42, the prompt at the right appears.
Enter the group number to which the time window will apply.
Press [∗] to accept entry. The "Time Window ?" prompt
appears.
Actions 55-60
If you selected actions 55-60, the prompt at the right
appears. Enter the access point number.
Press [∗] to accept entry. The "Time Window ?" prompt
appears.
5-12
ACTION SPECIFIER
01 RELAY # ?
00
01 RELAY GRP # ?
00
PART? 1 2 3 4 5 6 7 8
HIT 0-8
X X
01 ZONE LIST ?
ENTER 01-15
01
GROUP ?1 2 3 4 5 6 7 8
HIT 0-8
X
01 ACCESS POINT #
000