Section 15 : Contact Id Codes; Table Of Contact Id Codes - Honeywell VISTA-128BPT Installation And Setup Manual

Commercial burglary partitioned security system with scheduling
Hide thumbs Also See for VISTA-128BPT:
Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

Table of Contact ID Codes

Code
Definition
110
Fire Alarm
111
Smoke Alarm
121
Duress
122
Silent Panic
123
Audible Panic
124
Duress Access Grant
125
Duress Egress Grant
131
Perimeter Burglary
132
Interior Burglary
133
24-Hour Burglary
134
Entry/Exit Burglary
135
Day/Night Burglary
140
ACS Zone Alarm
150
24-Hour Auxiliary
162
CO Alarm
301
AC Loss
302
Low System Battery
305
System Reset
306
Program Tamper
308
System Shutdown
309
Battery Test Fail
313
System Engineer Reset
320
ACS Relay Supervision
321
Bell 1 Trouble
332
Poll Loop Short-Trouble
333
Expansion Module Failure
338
ACS Module Low Battery
339
ACS Module Reset
342
ACS Module AC Loss
343
ACS Module Self-Test Fail
344
RF Receiver Jam Detect
354
Dialer Queue Overflow
373
Fire Loop Trouble
374
Exit Error by Zone
378
Cross Zone Trouble
380
Trouble (global)
381
Loss of Supervision (RF)
382
Loss of RPM Supervision
383
RPM Sensor Tamper
384
RF Transmitter Low Battery
385
Smoke Detector HI
386
Smoke Detector LO
389
Detector Self-Test Failed
401
O/C by User
403
Power-Up Armed/Auto-Arm
406
Cancel by User
407
Remote Arm/Disarm (Download)
408
Quick Arm
409
Keyswitch O/C
411
Callback Requested
421
Access Denied
422
Access Granted
423
Door Force Open

Section 15 : Contact ID Codes

Code
Definition
424
Egress Denied
425
Egress Granted
426
Door Prop Open
427
Access Point DSM Trouble
428
Access Point RTE Trouble
429
ACS Program Entry
430
ACS Program Exit
431
ACS Threat Change
432
Access Point Relay/Trigger Fail
433
Access Point RTE Shunt
434
Access Point DSM Shunt/Unshunt
441
Armed STAY
451
Early Open/Close
452
Late Open/Close
453
Fail to Open
454
Fail to Close
455
Auto-Arm Fail
459
Recent Close
501
ACS Reader Disable
520
ACS Relay Disable
570
Bypass
576
ACS Zone Shunt
577
ACS Point Bypass
579
Vent Zone Bypass
601
Panel Test via Compass Software
602
Communicator Test
606
Listen-In to Follow
607
Burglary Walk-Test
621
Event Log Reset
625
Time/Date Reset
631
Exception Schedule Change
632
Access Schedule Change
NOTE: If 2∗03 ULC S304 feature is enabled and there
is a phone line (or radio) failure and the panel
has exhausted its maximum attempts to send
reporting events to the central station, the panel
will hold the messages in a buffer and resend
upon restoral of the communication path. In
addition, old messages that are sent will
indicate that they are not current messages so
that the central station does not dispatch on
them.
In order to accomplish this, an event qualifier of
"6" will be sent in place of the "1" or "3"
character in the message. The "6" indicates that
the message is old. Events will be sent in
chronological order and will be time-stamped in
the system's event log
15-1
.