Master Keypad Setup and Operation

Although this system has eight actual partitions, it
provides an extra partition strictly for the purpose of
assigning keypads as Master keypads for the system.
• Assigning any keypad to Partition 9 (in Device
Programming in the #93 Menu Mode) identifies
that keypad a Master keypad.
• A Master keypad reflects the status of the entire
system (Partitions 1-8) on its display at one
time.
• This eliminates the need for a building security
officer to have to log on to various partitions
from one partition's keypad to find out where an
alarm has occurred.
• To Arm, Disarm, or Force Bypass from the
Master Console the user must be have
Authority in ALL partitions, and be Global in at
least 2 partitions. You will be prompted for only
the partitions the user is assigned global
access. Device address must be programmed
as "Global".
The following is a typical display:
S Y S T E M 1 2 3 4 5 6 7 8
S T A T U S R R N N A ∗ B
Possible status indications include:
A
Armed Away
R
S
N
Armed Stay
M
Armed
B
Maximum
C
Comm Failure
I
Armed Instant
T
To obtain more information regarding a particular
partition, enter [∗] + Partition No. (e.g., [∗] + [4]). This
allows viewing only of that partition. In order to
affect that partition, the user must use a code that
has access to that partition.
Also, in order for a user of any partition to log on to
Partition 9 to view the status of all partitions, that
user must have access to all partitions. Otherwise,
access is denied.
The following is displayed for a fault condition on
Zone 2 (Loading Dock Window) on Partition 1
(Warehouse) when a user logs on from a keypad on
Partition:
Ready
F
Fire Alarm
P
Not Ready
AC Power
Bypass/
L
Low System
Ready
Battery
Alarm
Trouble
WHSE DISARMED
HIT ∗ FOR FAULTS
Pressing [∗] causes the following display to appear at
Partition 1's keypad(s):
FAULT 002 LOADING
DOCK WINDOW
Additional zone faults are displayed one at a time. To
display a new partition's status, press [∗] + Partition No.
• The Armed LED on a Master keypad is lit only if all
partitions have been armed successfully.
The Ready LED is lit only if all partitions are "Ready
to Arm."
• The Ready LED is lit if only one partition is armed.
• Neither LED is lit if only some partitions are armed
and/or only some partitions are ready.
Press [∗] + [0] or [∗] + [9] to return to the master
partition. Otherwise, if no keys are pressed for 2 minutes,
the system automatically returns to the master partition
The sounder on a Master keypad reflects the sound of the
most critical condition on all of the partitions. The priority
of the sounds, from most to least critical, is as follows:
1. Pulsing fire alarm sounds
2. T4 CO alarm sounds
3. Steady burglar alarm sounds
4. Trouble sounds (rapid beeping)
Silence the sounder by pressing any key on the Master
keypad or a keypad on the partition where the condition
exists.
A Master keypad uses the same panics
as Partition 1. Master keypad panics are
sent to
Partition 1, and will activate on Partition
1. Therefore, panics must be
programmed for Partition 1.