Scheduling Menu Structure

To program schedules, enter Scheduling Program Mode:
Installer Code + [#] + [80]. (Installer or Master level user code.)
Scheduling Program Mode can be entered only when all partitions are disarmed.
There are 6 sections of scheduling menus accessed via #80, as shown below. Entering 1 at a displayed main menu
prompt selects that menu section. Enter 0 to skip a section and display the next menu option.
PROMPT
Time Window ?
1 = YES 0 = NO
O/C Schedules ?
1 = YES 0 = NO
Holidays ?
1 = YES 0 = NO
Timed Events ?
1 = YES 0 = NO
Access Sched. ?
1 = YES 0 = NO
Quit ?
1 = YES 0 = NO

Time Windows

The system provides 20 time windows that are defined with start and stop times. These windows are used for various
open/close and access schedules, as well as for output controls, and are the basis of the scheduling system. These
windows are shared among all eight partitions.
Time Windows Worksheet
The following worksheet is an example of the worksheet found in the Programming Guide. This worksheet will help
you define time windows and scheduling aspects of this system before you program them. Note that time windows
can span midnight; for example, from 11 PM to 1 AM.
Time Window
Number
1
2
3.....20
A time window must have a start and a stop time.
EXPLANATION
Upon entering Schedule Menu Mode, this prompt appears. Enter 1 to program time windows.
Refer to Time Windows Programming later in this section for detailed procedures.
0
Enter 0 to move to the "O/C Schedules?" prompt.
Enter 1 to program opening and closing schedules. Refer to Open/Close Schedules
Programming later in this section for detailed procedures.
0
Enter 0 to move to the "Holidays?" prompt.
Enter 1 to program holiday schedules. Refer to Holiday Schedule Programming later in this
section for detailed procedures.
0
Enter 0 to move to the "Timed Events?" prompt.
Enter 1 to program timed events for relay outputs, additional schedules, and other system
functions. Refer to Time-Driven Event Programming later in this section for detailed procedures.
0
Enter 0 to move to the "Access Sched?" prompt.
Enter 1 to program access schedules. Refer to Limitation of Access Schedules Programming later
in this section for detailed procedures.
0
Enter 0 to move to the "Quit?" prompt.
Enter 1 to quit #80 Scheduling Menu Mode and return to normal operating mode.
Enter 0 to make any changes or review the scheduling programming options. If you press 0, the
0
"Time Window?" prompt is displayed.
Start Time
(HH:MM)
Stop Time
(HH:MM)