VISTA-128BPT/128BPT-SIA/250BPT INSTALLATION AND SETUP GUIDE

Bank Safe and Vault Example

The Bank Safe or Vault should be limited to its own partition where only a Master or Manager code would be allowed to
operate 24-hours a day, whereas regular users can only operate between 6am and 10pm (see Section 2 of this Manual
- Partitioning). To limit (disable) access to regular users to outside the desired time window follow the programming as
shown below.
Desired Action
Panel will auto arm at 10pm Monday thru Saturday with no warning and Only Master/Manager can disarm between
10pm and 6am (they have 24 hour access).

#80 Programming

1. Enter Scheduling Mode by entering Installer Code + [#] + [80].
2. Select Time Windows, then enter the time below:
Window
Start
1
6:00am
2
9:30am
3. Enter 00 + ∗ to exit Time Windows.
4. Do not Quit Menu Mode, go to O/C Schedules.
5. Enter the Vault Partition #.
6. Assign Window 01 as the OP window and Window 02 as the Cl Window for Monday thru Saturday.
Part
Mon
Op
Cl
1
01
04
7. Exit Program mode.

Control Programming

1. 2∗05 = 00, Auto-Arm Delay (partition-specific) Arm
at 10pm.
2. 2∗06 = 00, Auto-Arm Warning Period (partition-
specific) No Warning Period.
3. 2∗07 = 00, Auto-Disarm Delay (partition-specific)
Disarm at 6am.
4. 2∗08 = 1, Force Arm (partition-specific) Enable.
5. 2∗10 = 1, Allow Disarming only during Arm/Disarm
Windows (partition-specific).
6. 2∗11 = 0, Allow Disarm Outside Window if Alarm
Occurs.
Disabling the Master/Manager Code
To also disable the Master/Manager from disarming
between 10pm and 6am limits all Master/Manager
codes access between 6am and 10pm Monday thru
Saturday. They will not work on Sunday or Holidays.
1
. Enter program mode Installers code + #80
2. Enter 'Time Windows' and Create window 03 for
6:00am-10:00pm, enter 00 + ∗ to exit Time
Windows
3. Do not Quit Menu Mode, go to Access Sched.
4. Create Access Sched 01 by assigning Window 03
to A1 Monday thru Saturday. Exit Program mode
5. Assign all Master and Manager Codes to Access
Schedule 01 when user codes are assigned.
Stop
Purpose
10:00pm
Monday-Saturday open window. (User must disarm within this window,
otherwise control will disarm and send a "Late to Disarm" the appropriate report.)
10:00pm
Monday-Saturday closing window (User must arm between 9:30pm and 10pm,
otherwise the panel will arm and send a "Late to Arm" message.)
Tues
Wed
Op
Cl
Op
Cl
01
04
01
04
Thur
Fri
Op
Cl
Op
Cl
Op
01
0
01
0
01
4
4
Removing the O/C schedule from Saturday
Open and Closed window can be removed from
schedule for Saturday to prevent regular users (if they
are enabled for this particular partition) from being
able to disarm on Saturday, and window can be
removed from Limit Access Group 1 for Saturday to
prevent Master/Manager Access on Saturday.
1 Enter the program mode Installer's code + #80.
2. Go to O/C Schedules.
3. Enter Vault Partition, go to Saturday and enter 00
for OP and CL window.
4. Go to Access Schedules.
5. Enter Schedule 01, go to Saturday and enter 00 for
Window A1. Exit program mode.
Holiday Schedules
Create selected Holidays in Holiday Programming and
assign to all partitions. Holiday window in Open/Close
Schedule remains empty to prevent regular users (if
they are enabled for this particular partition) from
being able to disarm on Holidays, and Limit Access
Group 1 Holiday Window can remain empty to prevent
Master/Manager Access on Holidays.
1. Enter program mode Installers code + #80.
2. Go to Holidays.
3. Enter Selected Holiday dates.
4. Exit program mode.
5-14
Sat
Sun
Cl
Op
Cl
Op
04
00
00
00
Hol
Cl
00

Advertisement