Scheduling Menu Mode

The #80 Scheduling Menu Mode is used to program most of the scheduling and timed-event options. Enter Installer
Code + [#] + [8] + [0] from the normal operating mode.
NOTE: Only users with an Installer or Master level user code may enter the #80 mode.
The following can be programmed while in this mode:
• Time windows
• Open/Close schedules to each partition
• Holiday schedules
• Time-Driven events (for system functions and relay activation)
• Limitation of access schedules
Some scheduling features are programmed in Data Field Programming Mode (Installer Code + 8 0 0 0). Some
features are programmed in the #93 Menu Mode. The programming scheduling fields are listed below.
System-Wide Fields:
∗04
Enable Random Timers
1∗74 –1∗75
Relay timeout values
2∗01-2∗02
Daylight saving time options
Allow disarming outside window if alarm
2∗11
occurs
Partition-Specific fields:
Auto-arm delay value
2∗05
Auto-arm warning time
2∗06
Auto-disarm delay value
2∗07
Force-arm enable
2∗08
Open/Close Reporting by Exception
2∗09
Restrict disarm only during windows
2∗10
#93 Menu Mode (System Group #3)
Scheduling related report codes
Event-driven options are programmed using Output Programming in #93 Menu Mode. Relay activation can also be
Time-Driven and that those are programmed using the #80 Menu Mode. Refer to the Time-Driven Event Programming
later in this section for the procedure.
Steps to Program Scheduling Options
This section contains examples of the worksheets only. For complete worksheets, see the Programming
Guide accompanying this Installation and Setup Guide.
In order to use #80 Scheduling Menu Mode, use the worksheets to do the following:
1.
Define time windows (up to 20)
2.
Define the daily open/close schedules (one schedule per day, per partition)
3.
Define the holidays to be used by the system (up to 16)
4.
Define limitation of access times (up to 8 schedules)
5.
Define the Time-Driven events (up to 20)
NOTE: Temporary schedules are programmed using #81 Menu Mode.
Use #80 Scheduling Menu Mode to perform the following functions:
1.
Program the time windows
2.
Program the open/close schedules
3.
Program the Time-Driven events
4.
Program the access schedules
SECTION 5: SCHEDULING OPTIONS