VISTA-128BPT/128BPT-SIA/250BPT INSTALLATION AND SETUP GUIDE
NOTES:
2*05 and 2*06 do not apply to "non-arming" triggers (such as relays using Time Driven Events).
2∗06 applies to Time Driven events and Open and Close schedules.
Extend Closing Window
A user can manually delay the arm (closing) time
window by 1 or 2 hours. This is done by entering a
keypad command (User Code + #82), which then
prompts the user to enter the desired extension time
of 1 or 2.
This feature is useful if a user must stay on the
premises later than usual.
The Auto-Arm delay and warning periods begin at the
end of the extension.
Force Arm
Force Arming is not a ULC Listed
ULC
feature and must be disabled for ULC
installations.
The Force Arm option causes the panel to attempt to
bypass any faulted zones prior to auto arming (panel
performs a force-arm).
This option is set in partition-specific program field
2∗08.
Auto Disarming
The system can automatically disarm a partition at
the end of a pre-determined opening (disarm) time
window.
The disarming time can be delayed by using the
Auto-Disarm Delay feature.
Disarm Delay
Auto-Disarm Delay provides a delay before auto
disarming. This delay is added to the end of the
disarm time window.
The delay is set in 4-minute increments, up to 56
minutes, in partition-specific program field 2∗07.

Figure 36: Scheduling Time Line

Restrict Disarming
This option allows disarming by users only during the
disarm time window and during the arming time
window (in case user needs to re-enter premises
after manually arming the partition).
This option is set in partition-specific field 2∗10. If
field 2∗10 is set, we highly recommend setting field
2∗11, as well. This field allows the partition to be
disarmed outside the arm/disarm time windows only
if the partition is in alarm.
Exception Reports
This option allows the reporting of openings and
closings to the central station only if the arming and
disarming occurs outside of the predetermined
opening and closing time windows. It is set in
partition-specific field 2∗09.
The system can be programmed to send Failed to
Open and Failed to Close reports if the partition is
not armed or disarmed by the end of the
corresponding time window.
Limitation of Access of Users by Time
A user's access to the system can be limited to a
certain time period. Outside this time, that user's
code is inactive. The system provides up to eight
access schedules, each consisting of two time
windows (typically one for opening, one for closing)
for each day of the week and two time windows for
holidays.
The access schedules are programmed in the #80
Menu Mode, and enabled when a user's access code
is added to the system.
If a user tries to operate the system outside the
schedule, the alpha keypad displays "Access Denied."
5-2