VISTA-128BPT/128BPT-SIA/250BPT INSTALLATION AND SETUP GUIDE
NOTE: If using Total Connect Remote Interactive
Services, the virtual keypad must be assigned
to a burglary partition, and the GOTO feature
(program field 2∗18) must be "0" (disabled) for
partition 1 (the fire partition) so that the Fire
system cannot be accessed remotely. This is
the system default setting.
•
Anti-Mask is used if an interior zone types 04
(interior) or 10 (interior with delay) and input type
Peripheral Devices
• Supports up to 31 addressable devices, (keypads,
RF receivers, relay modules, etc.).
• Supervises devices (keypads, RF receivers, and
relay modules) and individual relays (up to 32), as
well as system zones (RF receivers and keypad
panics).
Arming/Disarming and Bypassing
• Can arm the system with zones faulted (Vent
Zone). These zones are automatically bypassed
and can be programmed to automatically
unbypass when the zone restores.
• Can arm with entry/exit and interior type zones
faulted (Arm w/Fault). These zones must be
restored before the exit delay expires, otherwise an
alarm is generated.
• Vent zones cannot be used in UL
installations.
• You must disable the Force Arm
UL
option (used in conjunction with the
Arm w/Fault option), in UL
installations.
You must disable the Force Arm option
ULC
(used in conjunction with the Arm
w/Fault option), in ULC Installations.
• Provides global arming capability (ability to arm all
partitions the user code has access to in one
command).
• Can Quick Exit an armed premises without having
to disarm and then rearm the system.
06 (serial poll) are selected. The trouble report
code is used to report the masking.
•
A Smart contact option that may be selected for
devices that support this feature such as the
5193SDT Smoke Detector or PIRs.
•
Battery sensing hardware that can sense when the
battery voltage is too low and prevents deep
discharging from not occurring.
• Provides 96 outputs using 4204 Relay Modules
and V-PLEX Relay Modules that can activate
outputs in response to system events (alarm
condition), at a specific time of day, at random
times, and manually using the #70 Relay
Command Mode.
• Supports a Momentary Keyswitch on any one of
the system's eight partitions, using zone seven
(Event/Actions).
Quick Exit is not permitted for use with
UL
the VISTA-128BPT/VISTA-250BPT
Control Panel in a UL installation.
• Can be armed in one of three STAY modes or
Instant modes, automatically bypassing specific
burglary zones regardless of the zone response
type.
• Can automatically bypass specific zones if no one
exits the premises after arming (Auto-STAY). Auto-
STAY will not occur if the system is armed via an RF
transmitter, scheduling, access control, keyswitch,
RS232 (TB4) automation or downloading.
• Can bypass a group of zones with one set of
keystrokes.
• Supports Exit Error Logic, whereby the system can
tell the difference between a regular alarm and an
alarm caused by leaving an entry/exit door open. If
the system is not subsequently disarmed, faulted
E/E zone(s) and/or interior zones are bypassed
and the system arms.
• Supports Recent Close report, which is designed
to notify the central station that an alarm has
occurred within 2 minutes after the exit delay has
expired.
2-2