ABB IRC5 Product Manual page 60

Panel mounted controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

2 Installation and Commissioning, IRC5
2.5.3. Connecting communication cables between IRC5 Panel Mounted Drive Module and Control Module
Continued
Required equipment
Equipment
Ethernet cable
Panel board/Contactor interface
board cable
Standard toolkit
Circuit diagram
Connecting the Ethernet cable
The following procedure details how to connect the Ethernet cable between the Drive Module
and Control Module.
Connecting the Panel board/Contactor interface board cable
The following procedure details how to connect the Panel board/Contactor interface board
cable between the Drive Module and Control Module.
58
Action
1. Connect the cable to the Axis computer board
connector A42.X2, route and strap the cable as
shown in the illustration above.
2. Connect the cable to the Main computer connector
A32.A9.
Action
1. Connect the cable to the Contactor interface board
connector A43.X1, route and strap the cable as
shown in the illustration above.
2. Connect the cable to the Panel board connector
A21.X7.
Art. no.
Note
3HAC026292-001
3HAC024201-001
Described in section Standard
toolkit.
See
Note/Illustration
Note/Illustration
3HAC027707-001 Revision: D
Circuit Diagram on page
195.

Hide quick links: