ABB IRC5 Product Manual page 232

Panel mounted controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

1
2
3)
/26;3 / -+24Vdevicenet;2
/26;3 / -0Vdevicenet;2
/46;2 / -V-
/46;2 / -CAN_L
/46;2 / -CAN_H
/46;2 / -V+
/46;2 / -DRAIN
OR PREVIOUS
I/O UNIT
1) JUMPERS PLACED ACCORDING TO
THE ACTUAL NODE ADDRESS.
2) RESISTANS 120 OHM SHALL ALWAYS
BE CONNECTED IN THE FIRST AND THE
LAST CONNECTOR IN THE CAN-BUS CIRCUIT.
3) CONNECTED IN THE LAST CONNECTOR IN THE
CAN-BUS CIRCUIT.
4) FOR COMBI I/O DSQC 651, 8 INPUT, NO X4.
FOR DIGITAL I/O DSQC 652, 16 INPUT, X3 AND X4.
Latest revision:
Prepared by, date:
Approved by, date:
3
4
TO NEXT
I/O UNIT
2)
120 ohm
2
1
DIG. PART OF COMBI I/O AND DIG. I/O UNIT
-I/Ox
-X5
1 1
2 2
4 4
5 5
0V
3 3
NA0
6 6
NA1
7 7
1)
NA2
8 8
NA3
9 9
NA4
10
10
NA5
11
11
12
12
5
DSQC 651& 652
0V
Lab/Office:
IRC5 PANEL MOUNTED CONTROL
DIGITAL PART OF COMBI I/O AND
DIGITAL I/O UNIT
6
7
4)
XTXX.X3
-X3
INPUT CH.1
2
1 1
3
2 2
4
3 3
5
4 4
6
5 5
7
6 6
8
7 7
0V
8 8
9 9
10
10
XTXX.X4
-X4
INPUT CH.9
10
1 1
11
2 2
12
3 3
13
4 4
14
5 5
15
6 6
16
7 7
0V
8 8
9 9
10
10
Status:
2008-09-01
Plant:
Location:
Approved
Sublocation:
Document no.
3HAC026871-005
8
=
CAB
+
CM
+
Rev. Ind
Page 43
Next
44
03
Total
69

Hide quick links: