Cfd Service-Instance Maid Format - HP 7500 Series High Availability Command Reference

Hide thumbs Also See for 7500 Series:
Table of Contents

Advertisement

Default command level
2: System level
Parameters
service-instance instance-id: Specifies a service instance by its ID, which ranges from 1 to 32767.
md md-name: Specifies the name of an MD. The md-name argument is a string of 1 to 43 characters.
IEEE 802.1ag standard version allows an MD name to contain letters, numbers, and special characters
such as tilde (~), exclamation mark (!), at sign (@), number sign (#), dollar sign ($), percent (%), caret
(^), ampersand (&), asterisk(*), brackets ({ }, ( ),[ ], < >), hyphen (-), underscore (_), plus (+), equal sign
(=), vertical bar (|), backslash (\), colon (:), semicolon (;), quotation marks (", '), comma (,), period (.),
and slash (/). IEEE 802.1ag draft5.2 version and IEEE 802.1ag draft5.2 interim version allow an MD
name to contain letters, numbers, and special characters such as hyphen (–) and underscore (_), but do
not allow an MD name to start or end with a special character.
ma ma-name: Specifies the name of an MA. The ma-name argument is a string of 1 to 43 characters.
IEEE 802.1ag standard version allows an MA name to contain letters, numbers, and special characters
such as tilde (~), exclamation mark (!), at sign (@), number sign (#), dollar sign ($), percent (%), caret
(^), ampersand (&), asterisk(*), brackets ({ }, ( ),[ ], < >), hyphen (-), underscore (_), plus (+), equal sign
(=), vertical bar (|), backslash (\), colon (:), semicolon (;), quotation marks (", '), comma (,), period (.),
and slash (/). IEEE 802.1ag draft5.2 version and IEEE 802.1ag draft5.2 interim version allow an MA
name to contain letters, numbers, and special characters such as hyphen (–) and underscore (_), but do
not allow an MA name to start or end with a special character.
Usage guidelines
Create the relevant MD and MA before you create a service instance with the MD name.
The service instance ID uniquely identifies an MA in an MD.
Deleting a service instance also deletes the configurations related to that service instance.
Deleting a service instance breaks up the connection between the service instance and the relevant MA,
the MA itself is not deleted.
A service instance with the MD name takes effect in all versions of CFD.
Examples
# Create a level-3 MD named test_md, create an MA named test_ma, which serves VLAN 100, in
test_md, and then create service instance 5 with the MD name for test_md and test_ma.
<Sysname> system-view
[Sysname] cfd md test_md level 3
[Sysname] cfd ma test_ma md test_md vlan 100
[Sysname] cfd service-instance 5 md test_md ma test_ma

cfd service-instance maid format

Use cfd service-instance maid format to create a service instance without the MD name.
Use undo cfd service-instance to remove the specified service instance.
Syntax
cfd service-instance instance-id maid format { icc-based ma-name | string ma-name } level level-value
vlan vlan-id
undo cfd service-instance instance-id
35