HP 7500 Series High Availability Command Reference page 145

Hide thumbs Also See for 7500 Series:
Table of Contents

Advertisement

Track ID: 3
Status: Negative
Duration: 0 days 0 hours 0 minutes 32 seconds
Notification delay: Positive 20, Negative 30 (in seconds)
Reference object:
Track interface
Interface status : Inserted
Interface
Protocol
Table 38 Command output
Field
Track ID
Status
notify 13 seconds later
Duration
Notification delay: Positive 20,
Negative 30 (in seconds)
Reference object
NQA entry
Reaction
BFD session
Packet type
Interface
Remote IP
Local IP
Track interface
Interface status
Interface
:
: Vlan-interface3
: IPv4
Description
ID of a track entry.
Status of a track entry:
Positive—The tracked object is operating properly.
Invalid—The tracked object is invalid.
Negative—The tracked object is abnormal.
The track module notifies the application modules of the track entry
state change 13 seconds later. The information is not displayed
after the track module notifies the application modules.
Time period during which the track entry stays in the state.
The track module notifies the application modules that the status
of the track entry has changed to Positive after a delay time of 20
seconds.
The track module notifies the application modules that the status
of the track entry has changed to Negative after a delay time of
30 seconds.
Tracked object associated with the track entry.
NQA test group associated with the track entry.
Reaction entry associated with the track entry.
Information about the BFD session associated with the track entry.
Type of BFD session packets, which can only be Echo.
Outgoing interface of BFD echo packets.
Remote IP address of the BFD echo packets.
Local IP address of the BFD echo packets.
Information about the interface associated with the track entry.
Interface status:
Inserted.
Removed.
Interface to be monitored.
139