Default
The errored frame seconds event triggering threshold is 1.
Views
System view
Default command level
2: System level
Parameters
threshold-value: Errored frame seconds event triggering threshold, ranging from 0 to 900.
Examples
# Set the errored frame seconds event triggering threshold to 100.
<Sysname> system-view
[Sysname] oam errored-frame-seconds threshold 100
Related commands
•
oam errored-frame-seconds period
display oam link-event
•
display oam configuration
•
oam errored-symbol period
Use oam errored-symbol period to set the errored symbol event detection interval.
Use undo oam errored-symbol period to restore the default.
Syntax
oam errored-symbol period period-value
undo oam errored-symbol period
Default
The errored symbol event detection interval is one second.
Views
System view
Default command level
2: System level
Parameters
period-value: Errored symbol event detection interval, ranging from 1 to 60 (in seconds).
Examples
# Set the errored symbol event detection interval to 10 seconds.
<Sysname> system-view
[Sysname] oam errored-symbol period 10
Related commands
•
oam errored-symbol threshold
display oam link-event
•
19