Oam Errored-Frame-Seconds Period; Oam Errored-Frame-Seconds Threshold - HP 7500 Series High Availability Command Reference

Hide thumbs Also See for 7500 Series:
Table of Contents

Advertisement

Examples
# Set the errored frame period event triggering threshold to 100.
<Sysname> system-view
[Sysname] oam errored-frame-period threshold 100
Related commands
oam errored-frame-period period
display oam link-event
display oam configuration

oam errored-frame-seconds period

Use oam errored-frame-seconds period to set the errored frame seconds event detection interval.
Use undo oam errored-frame-seconds period to restore the default.
Syntax
oam errored-frame-seconds period period-value
undo oam errored-frame-seconds period
Default
The errored frame seconds event detection interval is 60 seconds.
Views
System view
Default command level
2: System level
Parameters
period-value: Errored frame seconds event detection interval, ranging from 10 to 900 (in seconds).
Examples
# Set the errored frame seconds event detection interval to 100 seconds.
<Sysname> system-view
[Sysname] oam errored-frame-seconds period 100
Related commands

oam errored-frame-seconds threshold

display oam link-event
display oam configuration
oam errored-frame-seconds threshold
Use oam errored-frame-seconds threshold to set the errored frame seconds event triggering threshold.
Use undo oam errored-frame-seconds threshold to restore the default.
Syntax
oam errored-frame-seconds threshold threshold-value
undo oam errored-frame-seconds threshold