Commands to be used

Command name
Read contact area
Write contact area
Read data area
Write data area
Read timer/counter set
value area
Write timer/counter set
value area
Read timer/counter
elapsed value area
Write timer/counter
elapsed value area
Register or Reset
contacts monitored
Register or Reset data
monitored
Monitoring start
Preset contact area (fill
command)
Preset data area (fill
command)
Read system register
Write system register
Read the status of PLC
Remote control
Abort
Code
Description
RC
Reads the on and off status of contacts.
(RCS)
-Specifies only one point.
(RCP)
-Specifies multiple contacts.
(RCC)
-Specifies a range in word units.
WC
Turns contacts on or off.
(WCS)
-Specifies only one point.
(WCP)
-Specifies multiple contacts.
(WCC)
-Specifies a range in word units.
RD
Reads the contents of a data area.
WD
Writes data to a data area.
RS
Reads the timer/counter setting value.
WS
Writes the timer/counter setting value.
RK
Reads the timer/counter elapsed value.
WK
Writes the timer/counter elapsed value.
MC
Registers the contact to be monitored.
MD
Registers the data to be monitored.
MG
Monitors a registered contact or data using MD and MC.
Embeds the area of a specified range in a 16-point on and off
SC
pattern.
Writes the same contents to the data area of a specified
SD
range.
RR
Reads the contents of a system register.
WR
Specifies the contents of a system register.
Reads the specifications of the programmable controller and
RT
error codes if an error occurs.
Switches the operation mode of the programmable controller.
RM
(RUN mode <=> PROG. mode)
AB
Aborts communication.
7-11