Num
Name
-ber
Basic function instruction
F137
Auxiliary
timer (16-bit)
Special instructions
F138
Hours, min-
P138
utes and sec-
onds to
seconds data
F139
Seconds to
P139
hours,
minutes and
seconds data
F140
Carry flag
P140
(R9009) set
F141
Carry flag
P141
(R9009) reset
F142
Watching
P142
dog timer
update
F143
Partial I/O
P143
update
F144
Serial data
communica-
tion control
F145
Data send
P145
F146
Data receive
P146
F145
Data send
P145
F146
Data receive
P146
F145
Data send
P145
F146
Data receive
P146
F145
Data send
P145
F146
Data receive
P146
F147
Printout
F148
Self-
P148
diagnostic
error set
F149
Message
P149
display
: Available,
: Not available,
*1) The instruction is available for FP0 T32 (V2.3 or later) and FP-e.
*2) This instruction is available for FP0 V1.20 or later and FP-e.
*3) This instruction is available for FP-X V1.20 or later and FPΣ 32k type.
*4) This instruction is available for FP-X V2.50 or later and FPΣ V3.20 or later.
15-54
Ope-
Boo-
lean
rand
STMR
S, D
Turns on the specified output and
R900D after 0.01 s × set value.
HMSS
S, D
Converts the hour, minute and second
PHMSS
data of (S+1, S) to seconds data, and
the converted data is stored in (D+1, D).
SHMS
S, D
Converts the seconds data of (S+1, S)
PSHMS
to hour, minute and second data,
and the converted data is stored in
(D+1, D).
STC
-
Turns on the carry flag (R9009).
PSTC
CLC
-
Turns off the carry flag (R9009).
PCLC
WDT
S
The time (allowable scan time for the
PWDT
system) of watching dog timer is
changed to "S" × 0.1 (ms) for that scan.
IORF
D1, D2
Updates the I/O from the number
PIORF
specified by "D1" to the number
specified by "D2".
TRNS
S, n
The COM port received flag (R9038) is
set to off to enable reception.
Beginning at "S", "n" bytes of the data
registers are sent from the COM port.
SEND
S1, S2,
Sends the data to another station in the
PSEND
D, N
network (MEWNET). (via link unit)
RECV
S1, S2,
Receives the data to another station
PRECV
N, D
in the network (MEWNET). (via link unit)
SEND
S1, S2,
Sends the data to the slave station as
D, N
the MOD bus master. (via COM port)
RECV
S1, S2,
Receives the data from the slave station
N, D
as the MOD bus master. (via COM port)
SEND
S1, S2,
Sends the data to the slave station of
D, N
the MOD bus master, type II.
RECV
S1, S2,
Receives the data from the slave station
N, D
of the MOD bus master, type II.
SEND
S1, S2,
Sends the data to the slave station as
D, N
the MEWTOCOL master. (via COM
port)
RECV
S1, S2,
Receives the data from the slave station
N, D
as the MEWTOCOL master. (via COM
port)
PR
S, D
Converts the ASCII code data in the
area starting with "S" for printing, and
outputs it to the word external output
relay WY specified by "D".
ERR
n
Stores the self-diagnostic error number
PERR
(n: k100
"n" in (DT9000), turns R9000 on, and
to K299)
turns on the ERROR LED.
MSG
S
Displays the character constant of "S" in
PMSG
the connected programming tool.
: Not available partially
Description
5
5
*1
5
*1
1
1
3
5
5
*2
9
9
9
*3
9
*3
9
*4
*4
9
*4
*4
9
*3
*3
9
*3
*3
5
3
13

Advertisement