Panasonic FP0R User Manual page 332

Hide thumbs Also See for FP0R:
Table of Contents

Advertisement

Error
Name
code
Compile
E6
memory
full error
High-level
E7
instruction
type error
High-level
instruction
E8
operand
combina-
tion error
No
E9
program
error
Rewrite
during
E10
RUN
syntax
error
15-70
Opera-
tion
Description and steps to take
status
The program is too large to compile in the
program memory.
⇒ Change to PROG. mode and reduce the
total number of steps for the program.
Stops
-FP10SH
If memory expansion is possible, compilation
will become possible when the memory is
expanded.
In the program, high-level instructions, which
execute in every scan and at the leading edge
of the trigger, are programmed to be triggered
by one contact. (e.g. F0 (MV) and P0 (PMV)
Stops
are programmed using the same trigger
continuously.)
⇒ Correct the program so that the high-level
instructions executed in every scan and only
at the leading edge are triggered separately.
There is an incorrect operand in an instruction
which requires a specific combination of
Stops
operands (for example, the operands must all
be of a certain type).
⇒ Enter the correct combination of operands.
Program may be damaged.
Stops
⇒Try to send the program again.
When inputting with the programming tool
software, a deletion, addition or change of
Conti-
order of an instruction(ED, LBL, SUB, RET,
nues
INT, IRET, SSTP, and STPE) that cannot
perform a rewrite during RUN is being
attempted. Nothing is written to the CPU.
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A: Available
A
A
A
A
A
A
A
A
A
A