Status Indication; Frontal Leds; Status Display - Danfoss VLT Decentral Drive FCD 302 Operating Manual

Hide thumbs Also See for VLT Decentral Drive FCD 302:
Table of Contents

Advertisement

Status Indication

6 Status Indication

6.1 Frontal LEDs

The actual status can be read via 6 LEDs, which signal the
actual status of the unit. The meaning of each LED is
described in Table 6.1.
Illustration 6.1 Frontal LEDs
6
6
Name
Colour
ON
Green
Warning
Yellow
Alarm
Red
Bus MS
Only relevant if
optional fieldbus is
Bus NS1
present. See Profibus
Bus NS2
manual: MG34NXYY,
Ethernet manual:
MG90JXYY and
ProfiNet manual:
MG90UXYY, for
specific information.
Table 6.1 LED Status
60
VLT
ON
Warning
Alarm
Bus MS
NS1
NS2
Status
Indication
On
The frequency converter
receives power from mains
voltage, or external 24 V
supply.
Off
No power from mains
voltage, or external 24 V
supply.
On
Warning situation is present.
Off
No warning is present.
Flashing
Alarm is present.
Off
No alarm is present
Bus Module Status
Bus Network Status 1
Bus Network Status 2
Danfoss A/S © 05/2016 All rights reserved.
®
Decentral Drive FCD 302

6.2 Status Display

When the frequency converter is in status mode, status
messages are generated automatically from within the
frequency converter and appear in the bottom line of the
display (see Illustration 6.2.)
Status
799RPM
Auto
Hand
a
Illustration 6.2 Status Display
a.
The first word in the status line indicates where
the stop/start command originates.
b.
The second word in the status line indicates
where the speed control originates.
c.
The last part of the status line gives the present
frequency converter status. These show the
operational mode the frequency converter is in.
NOTICE
In auto/remote mode, the frequency converter requires
external commands to execute functions.
0.98A
0.000
53.2%
Remote
Ramping
Local
Stop
Running
Jogging
.
.
.
Stand by
b
c
1(1)
0.75kW
MG04F402