Programming

5.3 Parameter Lists

Changes during operation
"TRUE" means that the parameter can be changed while
the frequency converter is in operation and "FALSE" means
that it must be stopped before a change can be made.
4-Set-up
'All set-up': the parameters can be set individually in each
of the four set-ups, that is, one single parameter can have
four different data values.
In all set-ups '1 set-up': data value is the same.
5
5
Conversion index
This number refers to a conversion figure used when
writing or reading to and from the frequency converter.
Conv. index
100
67
6
5
4
3
2
1
0
-1
-2
-3
-4
-5
-6
Data
Description
type
2
Integer 8
3
Integer 16
4
Integer 32
5
Unsigned 8
6
Unsigned 16
7
Unsigned 32
9
Visible String
33
Normalized value 2 bytes
35
Bit sequence of 16 boolean variables
54
Time difference w/o date
®
See the VLT
Decentral Drive FCD 302 Design Guide for
further information about data types 33, 35 and 54.
40
®
VLT
Decentral Drive FCD 302
Conv. factor
1
1/60
1000000
100000
10000
1000
100
10
1
0.1
0.01
0.001
0.0001
0.00001
0.000001
Type
Int8
Int16
Int32
Uint8
Uint16
Uint32
VisStr
N2
V2
TimD
Danfoss A/S © 05/2016 All rights reserved.
Parameters for the frequency converter are grouped into
various parameter groups for easy selection of the correct
parameters for optimized operation of the frequency
converter.
0-** Operation and Display parameters for basic
frequency converter settings
1-** Load and Motor parameters
2-** Brakes
3-** References and ramping parameters, includes
DigiPot function
4-** Limits Warnings, setting of limits and
warning parameters
5-** Digital inputs and outputs, includes relay
controls
6-** Analog inputs and outputs
7-** Controls, setting parameters for speed and
process controls
8-** Communication and option parameters,
setting of FC RS485 and FC USB port parameters.
9-** Profibus
13-** Smart Logic Control parameters
14-** Special function parameters
15-** Drive information parameters
16-** Read out parameters
17-** Motor Feedback Option parameters
30-** Special Features
MG04F402