Programming
16-87
Bus Readout Alarm/Warning
16-89
Configurable Alarm/Warning Word
16-9* Diagnosis Readouts
16-90
Alarm Word
16-91
Alarm Word 2
16-92
Warning Word
16-93
Warning Word 2
16-94
Ext. Status Word
5.3.15 17-** Motor Feedb.Option
5
5
Par-
Parameter description
ameter #
17-1* Inc. Enc. Interface
17-10
Signal Type
17-11
Resolution (PPR)
17-2* Abs. Enc. Interface
17-20
Protocol Selection
17-21
Resolution (Positions/Rev)
17-22
Multiturn Revolutions
17-24
SSI Data Length
17-25
Clock Rate
17-26
SSI Data Format
17-34
HIPERFACE Baudrate
17-5* Resolver Interface
17-50
Poles
17-51
Input Voltage
17-52
Input Frequency
17-53
Transformation Ratio
17-56
Encoder Sim. Resolution
17-59
Resolver Interface
17-6* Monitoring and App.
17-60
Feedback Direction
17-61
Feedback Signal Monitoring
17-7* Position Scaling
17-70
Position Unit
17-71
Position Unit Scale
17-72
Position Unit Numerator
17-73
Position Unit Denominator
17-74
Position Offset
17-75
Position Recovery at Power-up
17-76
Position Axis Mode
17-8* Position Homing
17-80
Homing Function
17-81
Home Sync Function
17-82
Home Position
17-83
Homing Speed
17-84
Homing Torque Limit
17-85
Homing Timout
17-9* Position Config
17-90
Absolute Position Mode
17-91
Relative Position Mode
58
®
VLT
Decentral Drive FCD 302
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
Default value
4 set-up
[1] RS422 (5V TTL)
All set-ups
1024 N/A
All set-ups
[0] None
All set-ups
ExpressionLimit
All set-ups
1 N/A
All set-ups
13 N/A
All set-ups
ExpressionLimit
All set-ups
[0] Gray code
All set-ups
[4] 9600
All set-ups
2 N/A
1 set-up
7 V
1 set-up
10 kHz
1 set-up
0.5 N/A
1 set-up
[0] Disabled
1 set-up
[0] Disabled
2 set-ups
[0] Clockwise
All set-ups
[1] Warning
All set-ups
[0] pu
All set-ups
0 N/A
All set-ups
1024 N/A
All set-ups
1 N/A
All set-ups
0 CustomRea-
doutUnit2
All set-ups
[0] Off
All set-ups
[0] Linear Axis
All set-ups
[0] No Homing
All set-ups
[0] 1st time after
power
All set-ups
0 N/A
All set-ups
150 RPM
All set-ups
160 %
All set-ups
60 s
All set-ups
[0] Standard
All set-ups
[0] Target Position
All set-ups
Danfoss A/S © 05/2016 All rights reserved.
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
Change during
Conversion
operation
index
FALSE
FALSE
0
FALSE
FALSE
0
FALSE
0
FALSE
0
FALSE
3
FALSE
FALSE
FALSE
0
FALSE
-1
FALSE
2
FALSE
-1
FALSE
FALSE
FALSE
TRUE
TRUE
FALSE
0
FALSE
0
FALSE
0
FALSE
0
TRUE
TRUE
FALSE
FALSE
FALSE
0
TRUE
67
TRUE
0
TRUE
-1
FALSE
FALSE
Uint16
Uint16
Uint32
Uint32
Uint32
Uint32
Uint32
Type
Uint8
Uint16
Uint8
Uint32
Uint32
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Int8
Int32
Int32
Int32
Uint8
Uint8
Uint8
Uint8
Int32
Uint16
Uint16
Uint16
Uint8
Uint8
MG04F402