Programming
5.3.4 3-** Reference/Ramps
Par-
Parameter description
ameter #
3-0* Reference Limits
3-00
Reference Range
3-01
Reference/Feedback Unit
3-02
Minimum/Offset Reference
3-03
Maximum Reference
3-04
Reference Function
3-05
On Reference Window
3-06
Minimum Position
3-07
Maximum Position
3-08
On Target Window
3-09
On Target Time
3-1* References
3-10
Preset Reference
3-11
Jog Speed [Hz]
3-12
Catch up/slow Down Value
3-13
Reference Site
3-14
Preset Relative Reference
3-15
Reference Resource 1
3-16
Reference Resource 2
3-17
Reference Resource 3
3-18
Relative Scaling Reference Resource
3-19
Jog Speed [RPM]
3-2* References II
3-20
Preset Target
3-21
Touch Target
3-22
Master Scale Numerator
3-23
Master Scale Denominator
3-24
Master Lowpass Filter Time
3-25
Master Bus Resolution
3-26
Master Offset
3-4* Ramp 1
3-40
Ramp 1 Type
3-41
Ramp 1 Ramp Up Time
3-42
Ramp 1 Ramp Down Time
3-45
Ramp 1 S-ramp Ratio at Accel. Start
3-46
Ramp 1 S-ramp Ratio at Accel. End
3-47
Ramp 1 S-ramp Ratio at Decel. Start
3-48
Ramp 1 S-ramp Ratio at Decel. End
3-5* Ramp 2
3-50
Ramp 2 Type
3-51
Ramp 2 Ramp Up Time
3-52
Ramp 2 Ramp Down Time
3-55
Ramp 2 S-ramp Ratio at Accel. Start
MG04F402
Operating Guide
Default value
4 set-up
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Sum
All set-ups
ExpressionLimit
All set-ups
-100000 Custom-
ReadoutUnit2
All set-ups
100000 CustomRea-
doutUnit2
All set-ups
5 CustomRea-
doutUnit2
All set-ups
1 ms
All set-ups
0 %
All set-ups
ExpressionLimit
All set-ups
0 %
All set-ups
[0] Linked to
Hand / Auto
All set-ups
0 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] No function
All set-ups
ExpressionLimit
All set-ups
0 CustomRea-
doutUnit2
All set-ups
0 CustomRea-
doutUnit2
All set-ups
1 N/A
All set-ups
1 N/A
All set-ups
20 ms
All set-ups
65536 N/A
All set-ups
0 CustomRea-
doutUnit2
All set-ups
[0] Linear
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
50 %
All set-ups
50 %
All set-ups
50 %
All set-ups
50 %
All set-ups
[0] Linear
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
50 %
All set-ups
Danfoss A/S © 05/2016 All rights reserved.
Change during
Conversion
operation
index
TRUE
TRUE
TRUE
-3
TRUE
-3
TRUE
TRUE
-3
FALSE
0
FALSE
0
TRUE
0
TRUE
-3
TRUE
-2
TRUE
-1
TRUE
-2
TRUE
TRUE
-2
TRUE
TRUE
TRUE
TRUE
TRUE
67
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
-4
FALSE
0
TRUE
0
TRUE
TRUE
-2
TRUE
-2
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
TRUE
-2
TRUE
-2
TRUE
0
Type
Uint8
Uint8
Int32
Int32
Uint8
Int32
5
5
Int32
Int32
Int32
Uint16
Int16
Uint16
Int16
Uint8
Int32
Uint8
Uint8
Uint8
Uint8
Uint16
Int32
Int32
Int32
Int32
Uint16
Uint32
Int32
Uint8
Uint32
Uint32
Uint8
Uint8
Uint8
Uint8
Uint8
Uint32
Uint32
Uint8
45