Status Messages

8 Status Messages

8.1 Status Display

When the frequency converter is in status mode, status
messages are generated automatically and appear in the
bottom line of the display (see Illustration 8.1).
8
8
1 Operation mode (see Table 8.1)
2 Reference site (see Table 8.2)
3 Operation status (see Table 8.3)
Illustration 8.1 Status Display

8.2 Status Message Definitions Table

Table 8.1 to Table 8.3 describe the displayed status
messages.
Off
Auto On
Hand On
Table 8.1 Operation Mode
Remote
Local
Table 8.2 Reference Site
60
Operating Instructions
Status
799RPM
7.83A
0.000
53.2%
Auto
Remote
Ramping
Hand
Local
Stop
O
Running
Jogging
.
.
.
Stand by
1
2
3
The frequency converter does not react to any
control signal until [Auto On] or [Hand On] is
pressed.
The frequency converter is controlled from the
control terminals and/or the serial communi-
cation.
Control the unit via the navigation keys on
the LCP. Stop commands, reset, reversing, DC
brake, and other signals applied to the control
terminals can override local control.
The speed reference is given from external
signals, serial communication, or internal
preset references.
The frequency converter uses [Hand On]
control or reference values from the LCP.
Danfoss A/S © Rev. 2014-02-20 All rights reserved.
AC Brake
AMA finish OK
AMA ready
AMA running
1(1)
Braking
36.4kW
Braking max.
Coast
Ctrl. Ramp-down Control Ramp-down was selected in
Current High
Current Low
DC Hold
DC Stop
Feedback high
Feedback low
AC Brake was selected in 2-10 Brake Function.
The AC brake over-magnetises the motor to
achieve a controlled slow down.
Automatic motor adaptation (AMA) was
carried out successfully.
AMA is ready to start. Press [Hand On] to start.
AMA process is in progress.
The brake chopper is in operation. The brake
resistor absorbs generative energy.
The brake chopper is in operation. The power
limit for the brake resistor has been reached.
Coast inverse was selected as a function
for a digital input (parameter group 5–1*
Digital Inputs). The corresponding terminal
is not connected.
Coast activated by serial communication
14-10 Mains Failure.
The mains voltage is below the value set
in 14-11 Mains Voltage at Mains Fault at
mains fault
The frequency converter ramps down the
motor using a controlled ramp down
The frequency converter output current is
above the limit set in 4-51 Warning Current
High.
The frequency converter output current is
below the limit set in 4-52 Warning Speed Low
DC hold is selected in 1-80 Function at Stop
and a stop command is active. The motor is
held by a DC current set in 2-00 DC Hold/
Preheat Current.
The motor is held with a DC current (2-01 DC
Brake Current) for a specified time (2-02 DC
Braking Time).
DC brake is activated in 2-03 DC Brake Cut
In Speed [RPM] and a stop command is
active.
DC brake (inverse) is selected as a function
for a digital input (parameter group 5–1*
Digital Inputs). The corresponding terminal
is not active.
The DC brake is activated via serial
communication.
The sum of all active feedbacks is above the
feedback limit set in 4-57 Warning Feedback
High.
The sum of all active feedbacks is below the
feedback limit set in 4-56 Warning Feedback
Low.
MG34U302