Danfoss VLT Decentral Drive FCD 302 Operating Manual page 52

Hide thumbs Also See for VLT Decentral Drive FCD 302:
Table of Contents

Advertisement

Programming
6-35
Term. X30/11 High Ref./Feedb. Value
6-36
Term. X30/11 Filter Time Constant
6-4* Analog Input 4
6-40
Terminal X30/12 Low Voltage
6-41
Terminal X30/12 High Voltage
6-44
Term. X30/12 Low Ref./Feedb. Value
6-45
Term. X30/12 High Ref./Feedb. Value
6-46
Term. X30/12 Filter Time Constant
6-5* Analog Output 1
6-50
Terminal 42 Output
5
5
6-51
Terminal 42 Output Min Scale
6-52
Terminal 42 Output Max Scale
6-53
Term 42 Output Bus Ctrl
6-54
Terminal 42 Output Timeout Preset
6-55
Analog Output Filter
6-6* Analog Output 2
6-60
Terminal X30/8 Output
6-61
Terminal X30/8 Min. Scale
6-62
Terminal X30/8 Max. Scale
6-63
Terminal X30/8 Bus Control
Terminal X30/8 Output Timeout
6-64
Preset
6-7* Analog Output 3
6-70
Terminal X45/1 Output
6-71
Terminal X45/1 Min. Scale
6-72
Terminal X45/1 Max. Scale
6-73
Terminal X45/1 Bus Control
Terminal X45/1 Output Timeout
6-74
Preset
6-8* Analog Output 4
6-80
Terminal X45/3 Output
6-81
Terminal X45/3 Min. Scale
6-82
Terminal X45/3 Max. Scale
6-83
Terminal X45/3 Bus Control
Terminal X45/3 Output Timeout
6-84
Preset
5.3.8 7-** Controllers
Par-
Parameter description
ameter #
7-0* Speed PID Ctrl.
7-00
Speed PID Feedback Source
7-01
Speed PID Droop
7-02
Speed PID Proportional Gain
7-03
Speed PID Integral Time
7-04
Speed PID Differentiation Time
7-05
Speed PID Diff. Gain Limit
7-06
Speed PID Lowpass Filter Time
7-07
Speed PID Feedback Gear Ratio
Speed PID Accel. Feed Forward
7-08
Factor
7-09
Speed PID Error Correction w/ Ramp
50
®
VLT
Decentral Drive FCD 302
ExpressionLimit
All set-ups
0.001 s
All set-ups
0.07 V
All set-ups
10 V
All set-ups
0 ReferenceFeed-
backUnit
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
ExpressionLimit
All set-ups
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
[0] Off
1 set-up
ExpressionLimit
All set-ups
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
ExpressionLimit
All set-ups
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
ExpressionLimit
All set-ups
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
Default value
4 set-up
ExpressionLimit
All set-ups
0 RPM
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
5 N/A
All set-ups
ExpressionLimit
All set-ups
1 N/A
All set-ups
0 %
All set-ups
300 RPM
All set-ups
Danfoss A/S © 05/2016 All rights reserved.
TRUE
-3
TRUE
-3
TRUE
-2
TRUE
-2
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
TRUE
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
Change during
Conversion
operation
index
FALSE
TRUE
67
TRUE
-3
TRUE
-4
TRUE
-4
TRUE
-1
TRUE
-4
FALSE
-4
TRUE
0
TRUE
67
Int32
Uint16
Int16
Int16
Int32
Int32
Uint16
Uint8
Int16
Int16
N2
Uint16
Uint8
Uint8
Int16
Int16
N2
Uint16
Uint8
Int16
Int16
N2
Uint16
Uint8
Int16
Int16
N2
Uint16
Type
Uint8
Uint16
Uint16
Uint32
Uint16
Uint16
Uint16
Uint32
Uint16
Uint32
MG04F402