Lenovo ThinkServer RD650 User Manual page 371

12 gb/s megaraid sas
Hide thumbs Also See for ThinkServer RD650:
Table of Contents

Advertisement

12Gb/s MegaRAID SAS Software User Guide
March 2014
Number
0x018d
Warning
0x018e
Warning
0x018f
Warning
0x0190
Information
0x0191
Critical
0x0192
Information
0x0193
Information
0x0194
Information
0x0195
Information
0x0196
Warning
0x0197
Information
0x0198
Information
0x0199
Information
0x019a
Information
0x019b
Information
0x019c
Information
0x019d
Information
0x019e
Information
0x019f
Information
0x01a0
Information
0x01a1
Information
0x01a2
Information
0x01a3
Information
0x01a4
Information
0x01a5
Critical
0x01a6
Progress
0x01a7
Information
0x01a8
Information
0x01a9
Information
Severity
Event Text
Level
Cache-vault microcode update
required
CacheCade (%s) capacity exceeds
maximum allowed size, extra
capacity is not used
LD (%s) protection information lost
Diagnostics passed for %s
Diagnostics failed for %s
Server Power capability Diagnostic
Test Started
Drive Cache settings enabled during
rebuild for %s
Drive Cache settings restored after
rebuild for %s
Drive %s commissioned as
Emergency spare
Reminder: Potential non-optimal
configuration due to drive %s
commissioned as emergency spare
Consistency Check suspended on %s Logged when the Consistency Check is suspended on an LD.
Consistency Check resumed on %s
Background Initialization suspended
on %s
Background Initialization resumed
on %
Reconstruction suspended on %s
Rebuild suspended on %
Replace Drive suspended on %s
Reminder: Consistency Check
suspended on %
Reminder: Background Initialization
suspended on %s
Reminder: Reconstruction
suspended on %s
Reminder: Rebuild suspended on %s Logged as a reminder when the Rebuild is suspended on a
Reminder: Replace Drive suspended
on %s
Reminder: Patrol Read suspended
Erase aborted on %s
Erase failed on %s (Error %02x)
Erase progress on %s is %s
Erase started on %s
Erase completed on %s
Erase aborted on %s
Generic Conditions when Each Event Occurs
Logged when the BMU is not in Normal mode and
Cache-vault microcode update required.
Logged when CacheCade capacity exceeds maximum
allowed size, extra capacity is not used.
Logged when the protection information is lost for an LD.
Logged when the SHIELD Diagnostics passed for a PD.
Logged when the SHIELD Diagnostics failed for a PD.
Logged when the Server Power capability Diagnostic Test
starts.
Logged when the Drive Cache settings enabled during
rebuild for a PD.
Logged when the Drive Cache settings restored after rebuild
for a PD.
Logged when the Drive commissioned as Emergency spare.
Logged when the PD being imported is an Emergency Spare.
Logged when the Consistency Check is resumed on an LD.
Logged when the Background Initialization is suspended on
an LD.
Logged when the Background Initialization is resumed on an
LD.
Logged when the Reconstruction is suspended on an LD.
Logged when the Rebuild is suspended on a PD.
Logged when the Replace is suspended on a PD.
Logged as a reminder when the Consistency Check is
suspended on an LD.
Logged as a reminder when the Background Initialization is
suspended on an LD.
Logged as a reminder when the Reconstruction is suspended
on an LD.
PD.
Logged as a reminder when Replace is suspended on a PD.
Logged as a reminder when the Patrol Read is suspended.
Logged when the Erase is aborted on a PD.
Logged when the Erase is failed on a PD along with the error.
Logged to display the Erase progress on a PD along with its
current progress.
Logged when Erase is started on a PD.
Logged when the Erase is completed on a PD.
Logged when the Erase is aborted on an LD.
LSI Corporation
- 371 -
Appendix A: Events and Messages