12Gb/s MegaRAID SAS Software User Guide
March 2014
Number
0x00a2
Information
0x00a3
Information
0x00a4
Information
0x00a5
Information
0x00a6
Critical
0x00a7
Information
0x00a8
Critical
0x00a9
Information
0x00aa
Critical
0x00ab
Critical
0x00ac
Information
0x00ad
Critical
0x00ae
Critical
0x00af
Information
0x00b0
Critical
0x00b1
Warning
0x00b2
Critical
0x00b3
Warning
0x00b4
Critical
0x00b5
Critical
0x00b6
Warning
0x00b7
Critical
0x00b8
Warning
0x00b9
Critical
Severity
Event Text
Level
Current capacity of the battery is
below threshold
Current capacity of the battery is
above threshold
Enclosure (SES) discovered on %s
Enclosure (SAFTE) discovered on %s Not logged by the firmware.
Enclosure %s communication lost
Enclosure %s communication
restored
Enclosure %s fan %d failed
Enclosure %s fan %d inserted
Enclosure %s fan %d removed
Enclosure %s power supply %d failed Not logged by the firmware.
Enclosure %s power supply %d
inserted
Enclosure %s power supply %d
removed
Enclosure %s SIM %d failed
Enclosure %s SIM %d inserted
Enclosure %s SIM %d removed
Enclosure %s temperature sensor %d
below warning threshold
Enclosure %s temperature sensor %d
below error threshold
Enclosure %s temperature sensor %d
above warning threshold
Enclosure %s temperature sensor %d
above error threshold
Enclosure %s shutdown
Enclosure %s not supported; too
many enclosures connected to port
Enclosure %s firmware mismatch
Enclosure %s sensor %d bad
Enclosure %s phy %d bad
Generic Conditions when Each Event Occurs
Logged as part of monitoring the battery status when the
capacity of the battery is below threshold.
Logged as part of monitoring the battery status when the
capacity of the battery is above threshold.
Logged when an Enclosure (SES) is discovered for the first
time.
Logged when the communication with an enclosure has
been lost.
Logged when the communication with an enclosure has
been restored
Logged when an enclosure fan has failed.
Logged when an enclosure fan has been inserted newly.
Logged when an enclosure fan has been removed.
Logged when power supply has been inserted to an
enclosure.
Logged when power supply has been removed from an
enclosure.
Logged when the enclosure SIM has failed.
Logged when an enclosure SIM has been inserted.
Logged when an enclosure initialization was completed but
later the SIM was removed.
Logged when the enclosure services process has detected a
temperature lower than a normal operating temperature or
lower than the value indicated by the LOW WARNING
THRESHOLD field in the Threshold In diagnostic page.
Logged when the enclosure services process has detected a
temperature lower than a safe operating temperature or
lower than the value indicated by the LOW CRITICAL
THRESHOLD field in the Threshold In diagnostic page.
Logged when the enclosure services process has detected a
temperature higher than a normal operating temperature or
higher than the value indicated by the HIGH WARNING
THRESHOLD field in the Threshold In diagnostic page.
Logged when the enclosure services process has detected a
temperature higher than a safe operating temperature or
higher than the value indicated by the HIGH CRITICAL
THRESHOLD field in the Threshold In diagnostic page.
Logged when an unrecoverable condition is detected in the
enclosure.
Logged when the maximum allowed enclosures per port is
exceeded.
Logged when two ESMs have different firmware versions.
Logged when the device is present on the phy, but the status
does not indicate its presence.
Logged when the status indicates a device presence, but
there is no corresponding SAS address is associated with the
device.
LSI Corporation
- 362 -
Appendix A: Events and Messages