Lenovo ThinkServer RD650 User Manual page 359

12 gb/s megaraid sas
Hide thumbs Also See for ThinkServer RD650:
Table of Contents

Advertisement

12Gb/s MegaRAID SAS Software User Guide
March 2014
Number
0x0058
Information
0x0059
Information
0x005a
Critical
0x005b
Information
0x005c
Warning
0x005d
Warning
0x005e
Progress
0x005f
Fatal
0x0060
Critical
0x0061
Fatal
0x0062
Information
0x0063
Information
0x0064
Information
0x0065
Critical
0x0066
Critical
0x0067
Progress
0x0068
Information
0x0069
Information
0x006a
Information
0x006b
Critical
0x006c
Fatal
0x006d
Fatal
0x006e
Information
0x006f
Fatal
0x0070
Information
Severity
Event Text
Level
Format complete on %s
Format started on %s
Hot Spare SMART polling failed on
%s (Error %02x)
Drive inserted: %s
Drive %s is not supported
Patrol Read corrected medium error
on %s at %lx
Patrol Read progress on %s is %s
Patrol Read found an uncorrectable
medium error on %s at %lx
Predictive failure: CDB: %s
Patrol Read puncturing bad block on
%s at %lx
Rebuild aborted by user on %s
Rebuild complete on %s
Rebuild complete on %s
Rebuild failed on %s due to source
drive error
Rebuild failed on %s due to target
drive error
Rebuild progress on %s is %s
Rebuild resumed on %s
Rebuild started on %s
Rebuild automatically started on %s Logged when the rebuild operation kicks in on a spare.
Rebuild stopped on %s due to loss of
cluster ownership
Reassign write operation failed on
%s at %lx
Unrecoverable medium error during
rebuild on %s at %lx
Corrected medium error during
recovery on %s at %lx
Unrecoverable medium error during
recovery on %s at %lx
Drive removed: %s
Generic Conditions when Each Event Occurs
Logged when Format has completed.
Logged when format unit is started on a PD.
Currently not logged.
Logged when drive is inserted and slot/enclosure fields of PD
are updated.
Logged when the drive is not supported; reason could be the
number of drive has exceeded the MAX supported drives or
an unsupported drive is inserted like a SATA drive in SAS only
enclosure or could be a unsupported drive type.
Logged when Patrol read has successfully completed
recovery read and recovered data.
Logs patrol read progress, the progress is logged only if the
progress is greater than 1% at an interval of every 15 seconds.
Logged when Patrol read is unable to recover data.
Logged when a failure is found during smart (predictive
failure) poll.
Logged when patrol read punctures a block due to
unrecoverable medium error.
Logged when the user aborts a rebuild operation.
Logged when the rebuild operation on a logical drive on a
physical drive (which may have multiple LDs) is completed.
Logged when rebuild operation is completed for all logical
drives on a given physical drive.
Logged if one of the source drives for the rebuild operation
fails or is removed.
Logged if the target rebuild drive (on which rebuild
operation is going on) fails or is removed from the controller.
Logged to indicate the progress (in percentage) of the
rebuild operation on a given physical drive.
Logged when the rebuild operation on a physical drive
resumes.
Logged when the rebuild operation is started on a physical
drive.
Logged when the rebuild operation is stopped due to loss of
ownership.
Logged when a check condition or medium error is
encountered for a reassigned write.
Logged when the rebuild I/O encounters an unrecoverable
medium error.
Logged when recovery completed successfully and fixed a
medium error.
Logged when the recovery for a failed I/O encounters a
medium error.
Logged when a drive is removed from the controller.
LSI Corporation
- 359 -
Appendix A: Events and Messages

Advertisement

Table of Contents
loading

Table of Contents