12Gb/s MegaRAID SAS Software User Guide
March 2014
Table 34 Advanced Battery Management Properties
Property
Start Manual Learn Cycle*
Set Automatic Learn Cycle
Properties*
Manufacturer
Serial Number
Date of Manufacture
Firmware Version
Status
Voltage
Current
Design Capacity
Full Capacity
Remaining Capacity
Auto-learn Mode
Next Learn Cycle Time
5.7.1.1

Setting Automatic Learn Cycle Properties

The Set Automatic Learn Cycle Properties dialog appears when you select Set Automatic Learn Cycle Properties
on the Advanced Battery Management dialog.
The small red arrow at the bottom of the dialog indicates that you can scroll down to view more options.
To generate an event as a reminder to start a learn cycle manually, highlight the field next to Generate an event...,
and press the spacebar.
To enable or disable automatic learn cycle mode, highlight the field next to Learn Cycle, press Enter, and make a
selection from the pop-up menu.
The Day, Time, No. of Days, and No. of Hours fields are also user-selectable through popup menus. The Next Learn
Cycle Time field shows the time of the next learn cycle.
Use the Apply, OK, and Cancel fields at the bottom of the selections (not visible in this figure) to apply, confirm or
cancel any changes to the learn cycle options.
5.7.2

Managing Enclosures

To manage enclosures and view enclosure properties, select Enclosure Management from the Advanced Hardware
Components menu.
The Enclosure Management dialog shows the firmware version and field replacement unit (FRU) number for the
selected enclosure. To select a different enclosure, highlight the Select Enclosure field, press Enter, and select the
enclosure from the pop-up menu.
To view a pop-up menu of drives connected to the enclosure, highlight the Attached Drives field and press Enter.
Highlight this field and press Enter to start a manual battery learn cycle.
Highlight this field and press Enter to set the properties for an automatic battery learn cycle.
Manufacturer of the battery.
Serial number of the battery.
Manufacturing date of the battery.
Firmware version of the battery.
Status of the battery. If the status is Learning, Degraded, or Failed, a reason is listed for the status.
Voltage level of the battery, in mV. Also indicates if the current battery voltage is normal or low.
Current of the battery, in mA.
Theoretical capacity of the battery.
Full charge capacity of the battery.
Remaining capacity of the battery.
Indicates whether auto-learn mode is enabled or disabled. A learn cycle is a battery calibration
operation that the controller performed periodically to determine the battery condition. This
operation cannot be disabled.
Date and hour of the next scheduled learn cycle.
NOTE
The red arrow appears when there is too much information to display
in one dialog. The amount of information that can be displayed in one
dialog depends on the capabilities of the HII browser.