Lenovo ThinkServer RD650 User Manual page 129

12 gb/s megaraid sas
Hide thumbs Also See for ThinkServer RD650:
Table of Contents

Advertisement

12Gb/s MegaRAID SAS Software User Guide
March 2014
Figure 93 Controller Firmware Update
Follow these steps to upgrade the firmware:
1.
To specify the file system where the.rom update file resides, highlight Select File System and press Enter. Select
the file system and press Enter.
2.
To specify the directory where the.rom file resides, highlight Select Directory and press Enter. Browse to the
required the directory and press Enter.
The current directory is normally highlighted. You may browse to only one level higher or one level lower.
3.
To specify the.rom file, highlight Select Image and press Enter. Select the.rom file and press Enter.
4.
Highlight Update and press Enter.
The following Warning dialog appears.
Figure 94 Firmware Update Warning
5.
Highlight the Confirm check box and press the spacebar to select the check box.
LSI Corporation
- 129 -
Chapter 5: The HII Configuration Utility
Managing Controllers

Advertisement

Table of Contents
loading

Table of Contents