Number
0x0107
Warning
0x0108
Warning
0x0109
Information
0x010a
Information
0x010b
Warning
0x010c
Warning
0x010d
Warning
0x010e
Fatal
0x010f
Fatal
0x0110
Information
0x0111
Warning
0x0112
Warning
0x0113
Fatal
0x0114
Information
0x0115
Information
0x0116
Information
0x0117
Progress
0x0118
Information
0x0119
Information
0x011a
Critical
0x011b
Warning
0x011c
Information
0x011d
Information
0x011e
Information
Severity
Event Text
Level
Foreign configuration table overflow Logged when the number of GUIDs to import exceeds the
Partial foreign configuration
imported, PDs not imported:%s
Connector %s is active
Board Revision %s
Command timeout on PD %s,
CDB:%s
PD %s reset (Type %02x)
VD bad block table on %s is 80% full Logged when number of Bad Blocks entries is at 80 % of what
VD bad block table on %s is full;
unable to log block %lx (on %s at
%lx)
Uncorrectable medium error logged
for %s at %lx (on %s at %lx)
VD medium error corrected on %s at
%lx
Bad block table on PD %s is 100% full Logged when Bad block table is 100 % Full. Any more media
VD bad block table on PD %s is 100%
full
Controller needs replacement, IOP is
faulty
Replace Drive started on PD %s from
PD %s
Replace Drive aborted on PD %s and
src is PD %s
Replace Drive complete on PD %s
from PD %s
Replace Drive progress on PD %s is
%s
Replace Drive resumed on PD %s
from %s
Replace Drive automatically started
on PD %s from %s
Replace Drive failed on PD %s due to
source %s error
Early Power off warning was
unsuccessful
BBU FRU is %s
%s FRU is %s
Controller hardware revision ID %s
Generic Conditions when Each Event Occurs
total supported by the firmware.
Logged when all the foreign configuration drives could not
be imported.
Logged during initial boot when a SAS MUX connector is
found for the controller.
Logged during boot.
Logged when command to a PD Timesout.
Logged when PD is reset.
can be supported in the firmware.
Logged when number of Bad Blocks exceed what can be
supported in the firmware.
Logged when an uncorrectable medium error is detected.
Logged on the corrected medium error.
errors on this physical drive will not be logged in the bad
block table.
Logged when Bad block table is 100 % Full. Any more media
errors on this logical drive will not be logged in the bad block
table.
Currently not logged in the firmware.
Logged when Replace is started.
Logged when Replace is aborted.
Logged when Replace is completed.
Logged to provide the progress of Replace.
Logged when Replace operation is resumed.
Logged on automatic start of Replace.
Logged when the source physical drive of a Replace fails. The
Replace stops and rebuild starts on the destination physical
drive.
Currently not logged in the firmware.
Logged only for IBM.
Logged if FRU data is present. Logged only for IBM.