Lenovo ThinkServer RD650 User Manual page 368

12 gb/s megaraid sas
Hide thumbs Also See for ThinkServer RD650:
Table of Contents

Advertisement

12Gb/s MegaRAID SAS Software User Guide
March 2014
Number
0x0136
Information
0x0137
Information
0x0138
Warning
0x0139
Warning
0x013a
Information
0x013b
Warning
0x013c
Information
0x013d
Warning
0x013e
Information
0x013f
Information
0x0140
Information
0x0141
Information
0x0142
Fatal
0x0143
Fatal
0x0144
Fatal
0x0145
Information
0x0146
Information
0x0147
Warning
0x0148
Warning
0x0149
Warning
0x014a
Warning
0x014b
Information
0x014c
Information
0x014d
Information
0x014e
Information
0x014f
Information
0x0150
Caution
0x0151
Information
Severity
Event Text
Level
Drive security key from escrow,
verified
Drive security key changed
Drive security key, re-key operation
failed
Drive security key is invalid
Drive security key destroyed
Drive security key from escrow is
invalid
VD %s is now secured
VD %s is partially secured
PD %s security activated
PD %s security disabled
PD %s is reprovisioned
PD %s security key changed
Security subsystem problems
detected for PD %s
Controller cache pinned for missing
or offline VD %s
Controller cache pinned for missing
or offline VDs: %s
Controller cache discarded by user
for VDs: %s
Controller cache destaged for VD %s Logged when LD pinned cache is recovered.
Consistency Check started on an
inconsistent VD %s
Drive security key failure, cannot
access secured configuration
Drive security password from user is
invalid
Detected error with the remote
battery connector cable
Power state change on PD %s from
%s to %s
Enclosure %s element (SES code
0x%x) status changed
PD %s rebuild not possible as
HDD/CacheCade software mix is not
supported in a drive group
Replace Drive cannot be started on
PD %s from %s, as HDD/CacheCade
software mix is not supported in a
drive group
VD bad block table on %s is cleared
SAS topology error: 0x%lx
VD cluster of medium errors
corrected for %s at %lx (on %s at %lx)
Generic Conditions when Each Event Occurs
Logged when controller lock key is verified from escrow.
Logged when controller lock key is re-keyed.
Logged when controller lock re-key operation failed.
Logged when the controller lock is not valid.
Logged when the controller lock key is destroyed.
Logged when the controller escrow key is not valid. This
escrow key can not unlock any drive.
Logged when secure LD is created.
Logged when all the drives in the array are not secure.
Logged when PD security key is set.
Logged when security key is removed from an FDE drive.
Logged when PD security is cleared.
Logged when PD lock key is re-keyed.
Logged when PD security can not be set.
Logged when LD cache is pinned.
Logged when pinned cache is found during OCR.
Logged when LD pinned cache is discarded by the user.
Logged when consistency check is started on an inconsistent
LD.
Logged when an invalid lock key is detected.
Not logged.
Not logged.
Logged when PD power state (spun up, spun down,
in-transition) changes.
Not logged.
Logged when mixing violation occurs due to HDD/SSD
mismatch.
Logged when Replace could not be started on a PD because
HDD/CacheCade software mix was not supported in a drive
group.
Logged when a VD bad block table was cleared.
Logged when a SAS topology error occurred.
Logged when medium errors were corrected for a PD for a
LD.
LSI Corporation
- 368 -
Appendix A: Events and Messages

Advertisement

Table of Contents
loading

Table of Contents