Hypervisor Problems - Lenovo System x3550 M5 Installation And Service Manual

Machine type: 8869
Hide thumbs Also See for System x3550 M5:
Table of Contents

Advertisement

Table 9. Hard disk drive symptoms and actions (continued)
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
• Go to the Support Web site at http://www.lenovo.com/support to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Symptom
Multiple hard disk drives are
offline.
A replacement hard disk drive
does not rebuild.
A green hard disk drive activity
LED does not accurately
represent the actual state of
the associated drive.
A yellow hard disk drive status
LED does not accurately
represent the actual state of
the associated drive.

Hypervisor problems

Use this information to solve hypervisor problems.
Table 10. Hypervisor's symptoms and actions
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
• Go to the Support Web site at http://www.lenovo.com/support to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Symptom
If an optional embedded
hypervisor device is not listed
in the expected boot order,
does not appear in the list
of boot devices, or a similar
problem has occurred.
Action
1. Review the storage subsystem logs for indications of problems within the
storage subsystem, such as backplane or cable problems.
2. See "Problem determination tips" on page 90.
1. Make sure that the hard disk drive is recognized by the adapter (the green hard
disk drive activity LED is flashing).
2. Review the SAS/SATA adapter documentation to determine the correct
configuration parameters and settings.
If the green hard disk drive activity LED does not flash when the drive is in use, run
the DSA Preboot diagnostic programs to collect error logs (see "Running the DSA
Preboot diagnostic programs" on page 68).
• If there is a hard disk drive error log, replace the affected hard disk drive.
• If there is no disk drive error log error log, replace the affected backplane.
1. If the yellow hard disk drive LED and the RAID adapter software do not indicate
the same status for the drive, complete the following steps:
a. Turn off the server.
b. Reseat the SAS/SATA adapter.
c. Reseat the backplane signal cable and backplane power cable.
d. Reseat the hard disk drive.
e. Turn on the server and observe the activity of the hard disk drive LEDs.
2. See "Problem determination tips" on page 90.
Action
1. Make sure that the optional embedded hypervisor device is selected on the
boot manager <F12> Select Boot Device at startup.
2. Make sure that the embedded hypervisor device is seated in the connector
correctly (see "Replacing a USB embedded hypervisor flash device" on page
228 and "Replacing the SD adapter" on page 168).
3. See the documentation that comes with the optional embedded hypervisor
device for setup and configuration information.
4. Make sure that other software works on the server.
.
Chapter 3
Troubleshooting
73

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents