Lenovo System x3550 M5 Installation And Service Manual page 951

Machine type: 8869
Hide thumbs Also See for System x3550 M5:
Table of Contents

Advertisement

S.3108007 The default system settings have been restored. System Configuration Restored to
Defaults
Explanation:
Severity
Error
User Response
Complete the following steps:
1. Check Lenovo support site for an applicable service bulletin or firmware update that applies to
this error.
• S.3818004 The CRTM flash driver could not successfully flash the staging area. A failure occurred.
CRTM Update Failed
Explanation:
Severity
Error
User Response
Complete the following steps:
1. Continue booting the system. If the system does not reset, manually reset the system.
2. If the error is not reported on the subsequent boot, no additional recovery action is required.
3. If the error persists, continue booting system and update the UEFI image.
4. (Trained service technician only) Replace the system board.
• S.3818007 The firmware image capsules for both flash banks could not be verified. CRTM image
capsule could not be verified
Explanation:
Severity
Error
User Response
Complete the following steps:
1. If system failed to boot successfully, DC cycle system.
2. If system boots to F1 setup, update the UEFI image and reset bank to primary (if required). If the
system boots without error, recovery is complete and no additional action is required.
3. If system fails to boot, or if the firmware update attempt fails, (trained service technician only)
replace the system board.
S.51003 An uncorrectable memory error was detected in DIMM slot [arg1] on rank [arg2]. An
uncorrectable memory error was detected on processor [arg3] channel [arg4]. The failing DIMM
within the channel could not be determined. An uncorrectable memory error has been detected.
Fatal Memory Error Occurred
Explanation:
Appendix B. UEFI/POST diagnostic codes
937

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents