Lenovo System x3550 M5 Installation And Service Manual page 541

Machine type: 8869
Hide thumbs Also See for System x3550 M5:
Table of Contents

Advertisement

User Response
Reset the front USB cable on the system board.
806f011b-0c01ffff : The connector [PhysicalConnectorElementName] has encountered a
configuration error. (FP LCD Cable)
This message is for the use case when an implementation has detected an Interconnect Configuration
Error.
May also be shown as 806f011b0c01ffff or 0x806f011b0c01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0266
User Response
1. Check system event log is showing LCD cable sensor has deasserted.
2. Reseat LCD cable on the system board.
3. Reset LCD cable on LCD panel.
4. Replace LCD cable.
806f0123-2101ffff : Reboot of system [ComputerSystemElementName] initiated by
[WatchdogElementName]. (IPMI Watchdog)
This message is for the use case when an implementation has detected a Reboot by a Watchdog occurred.
May also be shown as 806f01232101ffff or 0x806f01232101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Appendix A. Integrated management module 2.1 (IMM2.1) error messages