Lenovo System x3550 M5 Installation And Service Manual page 427

Machine type: 8869
Hide thumbs Also See for System x3550 M5:
Table of Contents

Advertisement

Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
1. Reduce the ambient temperature.
2. Ensure the air baffle is installed correctly.
3. Check the server airflow. Make sure that nothing is blocking the air from coming into or
preventing the air from exiting the server.
• 80010901-1001ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has
asserted. (PCI 1 Amb Temp)
This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109011001ffff or 0x800109011001ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
1. Reduce the ambient temperature.
2. Ensure the air baffle is installed correctly.
3. Check the server airflow. Make sure that nothing is blocking the air from coming into or
preventing the air from exiting the server.
RAID Amb Temp : RR PCI1 Amb Temp :
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
413

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents