• 80010701-1001ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (PCI 1 Amb Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107011001ffff or 0x800107011001ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and
rear of the server), that the air baffle is in place and correctly installed, and that the server cover
is installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications (see Server
Features and specifications for more information).
3. Make sure that the heat sink for microprocessor n.
4. (Trained technician only) Replace system board.
RAID Amb Temp : RR PCI1 Amb Temp :
• 80010701-1002ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted. (PCI 2 Amb Temp)
This message is for the use case when an implementation has detected an Upper Non-critical sensor
going high has asserted.
May also be shown as 800107011002ffff or 0x800107011002ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
404
Lenovo System x3550 M5 Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents