Lenovo System x3550 M5 Installation And Service Manual page 774

Machine type: 8869
Hide thumbs Also See for System x3550 M5:
Table of Contents

Advertisement

Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Power On
SNMP Trap ID
24
CIM Information
Prefix: PLAT ID: 0107
User Response
No action; information only.
816f000d-0400ffff : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 0)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0400ffff or 0x816f000d0400ffff
Severity
Info
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
816f000d-0401ffff : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 1)
760