Lenovo System x3550 M5 Installation And Service Manual page 439

Machine type: 8869
Hide thumbs Also See for System x3550 M5:
Table of Contents

Advertisement

Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and
rear of the server), that the air baffle is in place and correctly installed, and that the server cover
is installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications (see Server
Features and specifications for more information).
3. Make sure that the heat sink for microprocessor n.
4. (Trained technician only) Replace system board.
RR PCI3 Amb Temp :
80010b01-1301ffff : Numeric sensor [NumericSensorElementName] going high (upper
non-recoverable) has asserted. (PSU 1 Amb Temp)
This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b011301ffff or 0x80010b011301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
1. Make sure that the fans are operating, that there are no obstructions to the airflow (front and
rear of the server), that the air baffle is in place and correctly installed, and that the server cover
is installed and completely closed.
2. Check the ambient temperature. You must be operating within the specifications (see Server
Features and specifications for more information).
3. Make sure that the heat sink for microprocessor n.
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
425

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents