3.
Use the Lenovo Power Configurator utility to determine current system
power consumption. For more information and to download the utility, go to
https://www.ibm.com/support/entry/myportal/docdisplay?lndocid=LNVO-PWRCONF.
4. Replace the power supply with higher rated power.
800b050a-1e81ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName]
has asserted. (Fan Zone 1)
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient
Resources.
May also be shown as 800b050a1e81ffff or 0x800b050a1e81ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0810
User Response
1. Make sure that the connectors on fan n are not damaged.
2. Make sure that the fan n connectors on the system board are not damaged.
3. Make sure that the fans are correctly installed.
4. Reseat the fans.
5. Replace the fans. (n = fan number)