Lenovo System x3550 M5 Installation And Service Manual page 781

Machine type: 8869
Hide thumbs Also See for System x3550 M5:
Table of Contents

Advertisement

3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
816f000d-040bffff : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 11)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d040bffff or 0x816f000d040bffff
Severity
Info
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4. Check the SAS cable.
816f000d-040cffff : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 12)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d040cffff or 0x816f000d040cffff
Severity
Info
Serviceable
Yes
Automatically notify support
No
Alert Category
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
767