Lenovo System x3550 M5 Installation And Service Manual page 660

Machine type: 8869
Hide thumbs Also See for System x3550 M5:
Table of Contents

Advertisement

Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
806f070c-2581ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (All DIMMS)
This message is for the use case when an implementation has detected a Memory DIMM configuration
error has been corrected.
May also be shown as 806f070c2581ffff or 0x806f070c2581ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology. One of the DIMMs :
806f070d-0400ffff : Rebuild in progress for Array in system [ComputerSystemElementName].
(Drive 0)
This message is for the use case when an implementation has detected that an Array Rebuild is in
Progress.
May also be shown as 806f070d0400ffff or 0x806f070d0400ffff
646
Lenovo System x3550 M5 Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents