Lenovo System x3550 M5 Installation And Service Manual page 64

Machine type: 8869
Hide thumbs Also See for System x3550 M5:
Table of Contents

Advertisement

• For Windows based operating systems:
– ibm_rndis_server_os.inf
– device.cat
• For Linux based operating systems:
– cdc_interface.sh
Step 4.
After you install Lenovo ToolsCenter Suite CLI, type the following commands to set the DMI:
onecli config set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model> [access_method]
onecli config set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n> [access_method]
onecli config set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag> [access_method]
Where:
<m/t_model>
The server machine type and model number. Type mtm xxxxyyy, where xxxx is the machine
type and yyy is the server model number.
<s/n>
The serial number on the server. Type sn zzzzzzz, where zzzzzzz is the serial number.
<asset_method>
The server asset tag number. Type asset aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa, where
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is the asset tag number.
[access_method]
The access method that you select to use from the following methods:
• Online authenticated LAN access, type the command: [­­imm
imm_user_id:imm_password@imm_internal_ip]
Where:
imm_internal_ip
The IMM2 internal LAN/USB IP address. The default value is 169.254.95.118.
imm_user_id
The IMM2 account (1 of 12 accounts). The default value is USERID.
imm_password
The IMM2 account password (1 of 12 accounts). The default value is PASSW0RD (with
a zero 0 not an O).
Note: If you do not specify any of these parameters, Lenovo ToolsCenter Suite CLI will use the
default values. When the default values are used and Lenovo ToolsCenter Suite CLI is unable to
access the IMM2 using the online authenticated LAN access method, Lenovo ToolsCenter Suite
CLI will automatically use the unauthenticated KCS access method.
Examples that do use the user ID and password default values:
onecli config set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
onecli config set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n>
onecli config set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
• Online KCS access (unauthenticated and user restricted): You do not need to specify a value for
access_method when you use this access method.
The KCS access method uses the IPMI/KCS interface. This method requires that the IPMI
driver be installed. Some operating systems have the IPMI driver installed by default. Lenovo
ToolsCenter Suite CLI provides the corresponding mapping layer. To download the Lenovo
ToolsCenter Suite CLI Users Guide, do the following:
50
Lenovo System x3550 M5 Installation and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents