Lenovo System x3550 M5 Installation And Service Manual page 647

Machine type: 8869
Hide thumbs Also See for System x3550 M5:
Table of Contents

Advertisement

3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
• 806f060d-0410ffff : Array [ComputerSystemElementName] has failed. (Ext Drive)
This message is for the use case when an implementation has detected that an Array Failed.
May also be shown as 806f060d0410ffff or 0x806f060d0410ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0176
User Response
1. Make sure that the RAID adapter firmware and hard disk drive firmware are at the latest level.
2. Make sure that the SAS cable is connected correctly.
3. Replace the SAS cable.
4. Replace the RAID adapter.
5. Replace the hard disk drive that is indicated by a lit status LED.
806f070c-2001ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 1)
This message is for the use case when an implementation has detected a Memory DIMM configuration
error has been corrected.
May also be shown as 806f070c2001ffff or 0x806f070c2001ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Appendix A. Integrated management module 2.1 (IMM2.1) error messages