Lenovo System x3550 M5 Installation And Service Manual page 655

Machine type: 8869
Hide thumbs Also See for System x3550 M5:
Table of Contents

Advertisement

Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
806f070c-200fffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 15)
This message is for the use case when an implementation has detected a Memory DIMM configuration
error has been corrected.
May also be shown as 806f070c200fffff or 0x806f070c200fffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0126
User Response
Make sure that DIMMs are installed in the correct sequence and have the same size, type, speed,
and technology.
806f070c-2010ffff : Configuration Error for [PhysicalMemoryElementName] on Subsystem
[MemoryElementName]. (DIMM 16)
This message is for the use case when an implementation has detected a Memory DIMM configuration
error has been corrected.
May also be shown as 806f070c2010ffff or 0x806f070c2010ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
641

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents