Functional description
The electrical connection is made through
originally sealed, push-out cable cut-outs
on the underside of the lower section of
the housing.
A wall bracket for wall mounting is located
on the rear of the lower section of the
housing.
DULCOMETER
®
D1Cc
The DULCOMETER
®
D1Cc is suitable for
control panel installation. In this respect if
fulfils the same functions as the D1Cb.
However, the D1Cc also has an option for
upgrading with a protective RC circuit.
When correctly installed, the D1Cc has an
IP54 protection rating.
2.2

Electrical construction

The device does not have a mains switch.
It is therefore immediately ready for ope‐
ration once connected to the power
supply.
The device processes an input signal
whilst taking into consideration operator
inputs. The result is displayed and made
available to other devices via a standard
signal. When equipped with actuators, the
device can also provide control functions.
It is designed to activate metering pumps,
solenoid valves, as well as an mA
standard signal output. The activation var‐
iable is recalculated every second.