FX2N-32DP-IF Profibus-DP Interface Unit
C-2-35: Simple Communication 6W-IF (Intel Format/Motorola Format)
Further information of the simple commnunication 6W-IF can be found in section 7.2.1 and
7.2.2.
Requirements:
• Cyclic data is 6 word inputs and 6 word outputs in every cycle.
Table C-69: Cyclic Data of Simple Communication 6W-IF
1st
2nd
3rd
4th
5th
6th
• Parameter is 4 bytes.
Table C-70: Simple Communication 6W-IF (Intel Format/Motorola Format)
Nr.
Parameter Name
00
SFB ID
(1st)
*1 Simple analog modules are FX
*2 These products are listed as shown when using the Intel format. When using the
Motorola format, the order of the products listed will change slightly.
(Intel Format/Motorola Format)
Send Data
FROM address
TO data
TO address
FROM address
TO data
TO address
Value Setting List
simple analog modules
*2
FX2N-4AD
FX2N-4AD-TC
FX2N-4AD-PT
*2
FX2N-4DA
*2
FX2N-1HC
*2
FX2N-1PG
*2
FX2N-20GM
*2
FX2N-10GM
*2
FX2N-232IF
FX2N-32ASI-M
-3A, FX
0N
FROM data
TO data (read back)
TO address (read back)
FROM data
TO data (read back)
TO address (read back)
*1
*2
*2
Special function block ID code
*2
-2AD and FX
2N
Receive Data
Description
-2DA.
2N
C-80
Appendix C: